Control Signals - Unitek BAMOCAR-D3 Manual

Digitalbattery-motor-controller for ecservomotors acinductionmotors dc-servo
Table of Contents

Advertisement

Electrical Installation
Digital logic- outputs ( open- emitter)
Logic outputs 1 to 3 are for laid out for 12/ 24 V and 1 A . Short time 2 A.
Attention : The auxiliary voltage is also the power supply for the logical outputs.
An energy saving program can be programmed. ( clocked output).
Logic output 4 ( brake 24 V, 3 A ) is available at terminal X 11.
Signal operation ready ( solid state relay) / ready BTB/RDY
Operation ready are off in case of fault indications, if Auxiliary voltage is low ( <10 V)
The function of indication „ under voltage in DC link " can be programmed.
BTB with or without under voltage monitoring . ( BTB-power )
Output
Plug
Output voltage
On-level
Off-level
Output current
Output current
Voltage reference
ground reference
Funktion
+24V for the logic and the auxiliary voltage
Observe the sum of all output currents!
GNDE logic ground
Status
Parameter
max. +24V
<1V
nom. 1A
max. 2A
+24V (X1:4)
GNDE(X1:10)
29