De l u x e C on t ro l Co o k & Ho l d
Op er a to r ' s Ma n u al
Continued from previous page
4.
Scroll
c
until "Probes Offsets" displays. Touch the ">" icon
Compare
5.
the probe temperature reading against 32°F (0°C).
Touch
the "+" or "–" symbols until the temperature displayed is 32°F (0°C).
Touch
the green check mark.
6.
Remove
the probe from the ice water.
7.
If the oven has multiple probes, repeat this procedure until all probes are
calibrated.
The probe is now calibrated.