Download Print this page

Naturela NPBC-V6T-2 User Manual page 26

Electronic controller for pellet stove with water jacket

Advertisement

Electronic pellet burner controller - NPBC-V6T-2
Display - „Brightness" field changes the brightness of the display. The "Display date" field
indicates whether the date should be displayed in the bottom bar of the main screen when there is
other information that is displayed - burner operating phase or error messages. When date display
loading is turned off, the date is still displayed, when there is no other display information in the
bottom row of the main screen. The "Auto lock" row activates the automatic lock on the main
screen 30 seconds after the last action. The "Dim" row activates screen dimming 30 seconds after
the last action. When you press a button, the screen returns to its normal brightness.
Pump Settings- Settings for the circulation pumps' work of the external heating installations. For
the Central heating pump with row "On" you can set the minimum temperature of the boiler to
which the pump can turn on, with "Hysteresis" row you can set the min. temperature of the boiler
to which the pump can work i.e. the pump will turn off if the temperature of the boiler is under
the parameter "On" minus Parameter Hysteresis. For DHW pump with row "WH set temp" is set
the temperature to which the boiler will heat the water heater and with "Hysteresis" row is
indicated at what temperature of the water heater (row " WH set temp '' minus row "Hysteresis")
the boiler must heat the water heater again. The CH pump (Central heating) is connected to output
PH, and DHW pump (Domestic hot water) is connected to PWH output of the controller.
Central heating
field
Domestic hot water
field
User Manual / ver. 1.2
http://www.naturela-bg.com/en/
page 26 of 41

Advertisement

loading

This manual is also suitable for:

Npbc-v6t-1Npbc-v6t