Diagnostic
Pressing the "►" button when the controller is in one of the text information screens, goes to the
"Diagnostics" screen, which is a list of information about all the registered errors and the exact
time and date of its occurrence. If there are more than 4 entries, the next or previous page is
displayed with the "▼" or "▲" buttons. Scrolling from a text information screen to the
"Diagnostics" screen can also be done by a gesture – slide to the left and the changing of the pages
with diagnostic data - by sliding up and down the screen length.
By pressing the button
displayed message "No information" and save the time and the date of the reset. When
"Diagnostics " screen is displayed you can see an entry with the event
the time from which is going to begin the new diagnostic information. The star symbol mark the
next registered event.
The messages that are possible to appeared on this screen are shown in table 2. The messages from
1 to 13 will also appear and as a message for an error on the bottom line of the main screen.
Table 2
Message
1
Back burning
2
Off boiler TS
3
Short boiler TS
4
Boiler Frost
5
Ignition Fail
6
Off RB Sensor
7
Short RB Sensor
8
Off WH Sensor
9
Short WH Sensor
10
Off PT Sensor
11
Short PT Sensor
12
High Flue gas temp
User Manual / ver. 1.2
Electronic pellet burner controller - NPBC-V6T-2
for more than 2 seconds, the diagnostic information is cleared and
Cleaning the
error
Button
automatically Boiler's temperature sensor is disconnected
automatically Boiler's temperature sensor is on short
Button
Button
automatically The back burning temperature sensor is disconnected
automatically The back burning temperature sensor is on short
automatically DHW temperature sensor is disconnected
automatically DHW temperature sensor is on short
automatically pt100 high temperature sensor is disconnected
automatically pt100 high temperature sensor is on short
Button
http://www.naturela-bg.com/en/
Description
The thermostat for back burning has been activated
The temperature in the boiler is below 0°C
The exhaust temperature is too high