Installation and Operating Instructions
CHAPTER 3
ELS-SHIPMENT AND
INSTALLATION
CHAPTER 4
INSTALLATION
ATTENTION
Fan-casing-type ELS-GUB..
3.0
ELS-GUB.. flame retardant polymer casing with fire protection encasement and fire protection shutter
– suitable for installation in buildings with fire protection requirement K90 and qualified fire protection funnel. Installation
in a qualified fire protection funnel. Discharge spigot lateral to the top and turnable to left or to the right by 90°.
3.1
Scope of delivery / Packing unit, fig. 1-2
ELS-GUB.. Fan casing flush mounted
œ
– Flush mounted casing ELS-GUB.. with fire protection encasement and quick plug connector for electrical
connection. Type also for second room ventilation available (ELS-GUBZ (L/R) and GUBRZ (L/R).
˜ Discharge spigot with airtight metal backdraught shutter, return spring included
™ Ramp
› Cable grommet
œ Cardboard cover plate
 Reversion kid ELS-ARS, discharge to the back (accessory for ELS-GUBA), store in casing until final assembly,
spiral insert only required to the final assembly
4.0
Installation location / position
If the ELS casings are fixed into resonance-strong plasterboards (e.g. flake board, gypsum cardboard or fibre
silicate plates), then the structure-borne sound is to be prevented by flexible intermediate inserts.
Presentation wall or ceiling, flush mounted installation
ELS
Bathroom
ELS
ELS-ZS
fig.1
˜
fig.3
ELS
Toilet
ELS
5
ELS-GUBR.. Fan casing flush mounted

œ
fig.4
ELS
Apartment kitchen
fig.6
fig.2
˜
fig.5