INSTRUCTIONS FOR ASSEMBLY
36.
Fill out nameplate data.
37.
For 6" pumps, install the nameplate by inserting
drive rivets (supplied) into the two pre-drilled holes
located on the motor bracket.
38.
For 8" and 10" pumps, attach nameplate to the
suction screen with two #6 machine screws and lock
nuts (supplied). Nuts will be on the inside of the
screen to eliminate possible interference with or
catching on the casing during installation.
TABLE 1.0
Collet Nut Torque Values
Pump GPM
Torque (Nm)
85
25
150
50
225
50
300
50
360
50
425
60
475
60
550
180
625
180
825
180
1150
300
12
TABLE 2.0
Metal Strap Torque Values
Pump GPM
Torque (Nm)
85
45
150
45
225
45
300
45
360
45
425
80
475
80
550
120
625
120
825
120
1150
120
37
38
TABLE 3.0
NEMA Shaft Dimension (in)
NEMA
Min
6"
2.8
8"
3.9
10"
3.9
Max
3.0
4.1
4.1

Advertisement

loading