SAFETY WARNINGS
BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
SAFETY
CAREFULLY READ THESE SAFETY
MESSAGES IN THIS MANUAL AND
ON PUMP.
CAUTION
DO NOT OPERATE THIS PUMP DRY!
Review instructions before operating.
Wear ear protection to reduce objectionable noise.
WARNING
Turn off power before servicing.
If fuel is spilled, avoid creating any source of ignition until
the fuel vapors have been cleaned up and removed.
This pump is suitable for installations where the vertical distance
from the pump to the water level does not exceed 25 ft. In off-
BASED ON 5' SUCTION LIFT.
30
Pump
Pump
Solids
Model
Size
Handling
FTSP-2 2'' x 2''
1 1/8''
198
FTSP-3 3'' x 3''
1 1/2 ''
318
FTSP-4 4'' x 4''
2''
616
NOTE:
This trash pump can handle pumping stones, leaves,
mud and other debris of sizes up to the listed solids handling for
the pump and up to 25% of the fl ow by volume.
FTSP SERIES SELF-PRIMING
TRASH PUMPS
OWNER'S MANUAL
Total Head in Feet
40
50
60
70
80
Capacity in U.S. Gallons per Minute
194
180
145
110
75
265
172
98
42
500
400
280
190
120
APPLICATION
set installations, friction losses in the suction pipe must be taken
into consideration.
PERFORMANCE
90
9
Pump
Model
40
FTSP-2
750
FTSP-3
1205
45
FTSP-4
2330
Total Head in Metres
12
15
18.5
21.5
Capacity in Litres per Minute
735
680
550
415
1005
650
370
160
1890
1515
1060
720
23.5
27.5
285
150
455
170

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTSP Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Franklin Electric FTSP Series

  • Page 1 FTSP SERIES SELF-PRIMING TRASH PUMPS OWNER'S MANUAL SAFETY WARNINGS BEFORE OPERATING OR INSTALLING THIS PUMP, READ THIS MANUAL AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. SAFETY CAREFULLY READ THESE SAFETY MESSAGES IN THIS MANUAL AND ON PUMP. CAUTION DO NOT OPERATE THIS PUMP DRY! •...
  • Page 2: Installation

    INSTALLATION (a) LOCATION: The pump should be installed in a dry and well lengths of suction hose are used, the suction pipe diameter ventilated location which provides adequate drainage, room should be increased by one size. This will increase the prim- for servicing and protection from freezing temperatures.
  • Page 3: Maintenance

    MAINTENANCE (a) LUBRICATION: the rear casing groove using thumbs only. Make sure that the smooth surface of the ceramic seat faces out- The pump requires no lubrication. wards. For gasoline or diesel engines, refer to the instructions Assemble the rear casing to the engine being very care- provided by the engine manuafacturer.
  • Page 4 THIS WARRANTY SETS FORTH THE COMPANY’S SOLE OBLIGATION AND PURCHASER’S EXCLUSIVE REMEDY FOR DEFECTIVE PRODUCT. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this warranty are free from defects in material or workmanship of the Company.
  • Page 5: Manuel Du Propriétaire

    SÉRIE FTSP POMPE À AMORÇAGE AUTOMATIQUE POUR EAUX CHARGÉES MANUEL DU PROPRIÉTAIRE CONSIGNES DE SÉCURITÉ AVA N T D ' I N S TA L L E R O U D'UTILISER CETTE POMPE, PRIÈRE DE LIRE LE PRÉSENT GUIDE ET SUIVRE TOUTES LES RÈGLES DE SÉCURITÉ...
  • Page 6 être dirigée vers la haut à partir de la source de liquide AVERTISSEMENT afi n d’empêcher qu’il ne s’y forme des poches d’air. Si • Toujours s’assurer que l’endroit est bien aéré afi n de prévenir la pompe doit souvent être réamorcée et s’il n’est pas l’asphyxie.
  • Page 7: Entretien

    ENTRETIEN (a) LUBRIFICATION : arrière du boîtier en n’appuyant qu’avec les pouces. La pompe n’exige aucune lubrifi cation. S’assurer que la surface lisse du siège de céramique Lubrifi er les moteurs à essence ou diesel selon les est orientée vers l’extérieur. instructions du fabricant.
  • Page 8 CE QUI A TRAIT À UN PRODUIT DÉFECTUEUX. Franklin Electric Company, Inc. et ses filiales (ci-après « la Société ») garantissent que les produits accompagnés de la présente garantie sont exempts de défauts de matériel et de main-d’œuvre liés à la Société.
  • Page 9: Manual Del Propietario

    SERIE FTSP BOMBAS DE DESPERDICIOS CON CARGADO AUTOMÁTICO MANUAL DEL PROPIETARIO ADVERTENCIAS DE SEGURIDAD LEA ESTE MANUAL Y SIGA T O D A S L A S R E G L A S D E S E G U R I D A D A N T E S D E INSTALAR U OPERAR ESTA BOMBA.
  • Page 10 conexiones, ni cortes o rajaduras en la manguera. Repare evita que la manguera se doble. En los casos en que se cualquier fuga, corte o rajadura, ya que reducen la capaci- necesite el volumen máximo por largos períodos de tiempo, dad de bombeo.
  • Page 11: Mantenimiento

    MANTENIMIENTO (a) LUBRICACIÓN: pulgares. Asegúrese que el lado liso del asiento de La bomba no necesita lubricación. cerámica esté hacia afuera. Para los modelos de motores de gasolina o diesel, vea las Ensamble el cuerpo posterior de la bomba al motor, instrucciones proporcionadas por el fabricante del motor.
  • Page 12 CORRESPONDE EXCLUSIVAMENTE AL COMPRADOR EN CASO DE QUE EL PRODUCTO SEA DEFECTUOSO. Franklin Electric Company, Inc. y sus subsidiarias (en adelante “la Compañía”) garantiza que los productos que cubre esta garantía carecen de defectos en cuanto al material o la mano de obra de la Compañía.

This manual is also suitable for:

Ftsp-2Ftsp-3Ftsp-4