Preparations For Use - Dräger Panorama Nova S - RA Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

The oxygen content of the ambient air must not fall below the
following limit values:
at least 17 Vol% oxygen in all European countries except the
Netherlands, Belgium and the UK
at least 19 Vol% oxygen in the Netherlands, Belgium, the UK,
Australia and New Zealand
In other countries, observe the applicable national regulations.
3.3

Preparations for use

 Use mask spectacles, if necessary.
3.4
Donning the mask/helmet combination and
checking the functional integrity
1. Adjust the adapter slot and the internal helmet components.
WARNING
!
To ensure leak tightness of the full face mask, the adapter slot
and internal helmet components must be precisely adjusted.
Extreme head shapes can lead to incompatibilities or leakag-
es.
2. Stroke any hair back off of your forehead. Your forehead must be
kept clear to ensure a tight fit of the full face mask.
3. Don the protective headgear, leave the chin strap open.
4. Place the carrying strap around your neck.
5. Take hold of both mask/helmet adapters, then slide the upper edge
of the full face mask against your forehead under the protective
headgear.
6. Pull both mask/helmet adapters backwards simultaneously to
tighten and clip them into the adapter slots in the protective
headgear.
Panorama Nova S - RA
7. Adjust the full face mask and loosely close the chin strap of the
protective headgear under your chin.
8. Ask an assistant to check the fit of the
full
face
elements
otherwise adjust the hairnet in the
protective headgear.
9. Seal the connector and inhale until a negative pressure is
generated. Hold your breath for a moment.
The negative pressure should be retained. No air may enter the full
face mask from the outside. Repeat the leak test twice.
10. Check the exhalation valve: Seal the connector and exhale
vigorously.
The exhaled air must be able to escape without obstruction
through the exhalation valve. If not, replace the exhalation valve.
11. Connect the self-contained breathing apparatus, airline equipment
or respiratory filter.
12. Check the proper fit by turning and pulling the lung demand valve
vigorously.
Have a second person check the tightness and correct connection.
WARNING
!
Only respond to an incident with a sealed mask/helmet
combination!
The full face mask may leak if a lamp holder is mounted on
the helmet and you push against an obstacle. Leaks reduce
the operation time and can lead to contaminants getting in the
device.
In this case, immediately exit the danger zone.
(approved by Dekra Exam)
mask.
The
tensioning
(1)
must
be
tightened,
Use
1
15

Advertisement

Table of Contents
loading

Table of Contents