Product Overview; Feature Description; Limitations On Use - Dräger Panorama Nova S - RA Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

2
Description
2.1

Product overview

6
5
4
3
2
1
15
14
12
13
1
Clamping ring
2
Inner mask
3
Visor
4
Visor frame
5
Mask/helmet adapter
6
Visor
7
Protective headgear
8
Adapter slot
Panorama Nova S - RA
7
8
9
10
11
01521315.eps
9
Neck guard
10 Chin strap
11 Carrying strap
12 Face seal
13 Exhalation valve cover
14 Connector
15 Full face mask
(approved by Dekra Exam)
2.2

Feature description

The full face masks have a round-thread connector in accordance with
EN 148-1:1999. This makes the full face masks suitable for respiratory
filters, normal-pressure self-contained breathing apparatuses and
normal-pressure airline equipment.
The full face mask is part of a mask/helmet combination. The full face
mask is mounted on the protective headgear with two mask/helmet
adapters.
NOTICE
i
i
These instructions for use describe the full face mask. For
information on the protective headgear, read the respective
instructions for use.
The full face masks can be used at temperatures from -30 °C to
+60 °C.
Mask spectacles can be inserted for users who wear spectacles.
2.3
Intended use
The full face masks protect the face and eyes against aggressive
media.
2.4

Limitations on use

WARNING
!
Beards and sideburns in the sealing area of the full face mask
will cause leakages! Therefore the full face mask should not
be used by anyone with facial hair of this sort. Earpieces in
the sealing area also cause leakages. Use special mask
spectacles.
Description
13

Advertisement

Table of Contents
loading

Table of Contents