2.5
Approvals
The full face masks are approved according to:
 EN 136:1998 Cl. 3+
 (EU) 2016/425
Declaration of conformity: see www.draeger.com/product-certificates
In addition, the full face masks comply with the requirements for flame
engulfment in EN 137:2006.
The full face masks may only be used with approved respiratory filters,
normal-pressure self-contained breathing apparatuses or normal-
pressure airline equipment.
The mask/helmet combination complies with DIN 58610:2014.
The following mask-helmet combinations are approved:
Panorama Nova S/HPS
Only use mask/helmet combinations with a water screen when in
hazardous areas.
2.6
Type-identical markings
The full face masks are marked as follows:
Connector
RA
EPDM
Mask body
EN 136:1998 CL. 3+
CExxxx (notified body in Europe)
PC (uncoated)
Visor
F (fire brigade)
14
3
Use
3.1

Preconditions for use

The mask/helmet combination needs to be carefully adapted to the
equipment wearer (adjustment of the adapter slot and internal
helmet components) due to the rigid structure.
3.2
Preconditions for use with respiratory filters
Together with a respiratory filter, the full face mask forms a filtering
device. Observe the following preconditions if the full face mask is
used as a filtering device:
The ambient conditions (particularly the types and concentrations
of contaminants) must be known. Use corresponding respiratory
filters. In cases where the contaminant is unknown, only use a self-
contained open-circuit breathing apparatus or an air line breathing
apparatus.
Only use filtering devices if the air does not directly endanger the
health or life of the user.
It must be ensured that the ambient atmosphere cannot change to
the worse.
Do not use filtering devices if there is suspicion of contaminants
with low warning properties (low-odour, tasteless, no irritation of
eyes and airways). A decreasing protective effect of the filtering
device cannot be determined in this case.
Do not use filtering devices for entering unventilated tanks, mines,
canals, etc.
Do not use filtering devices in oxygen-enriched atmospheres.
(approved by Dekra Exam)