Appendix 1 Specifications - Marathon Power Tri-Athlon ATWS-10003-02 User Manual

3-phase uninterruptible power system
Table of Contents

Advertisement

Model
Capacity
Input
Nominal Voltage
Operating Voltage Range
Operating Frequency Range
Power Factor
(full load/half load)
Harmonic Distortion
Bypass Voltage Range
Generator Input
Output
Output Voltage
Voltage Regulation
Power Factor
Output Frequency
Crest Factor
Harmonic Distortion (THD)
Efficiency
System Features
Transfer Time
Overload Line Mode
Overload Battery Mode
Overload Bypass Mode
Alarm
Protection
Communication
Environmental
Operating Temperature
Storage Temperature
Humidity Range
Altitude
Noise Level
Standards
Safety
EMC
Part Number
Weight
ATWS-10003-02
136kg (299.8lbs)
ATWS-15003-02
188kg (414.5lbs)
ATWS-20003-02
239kg (526.9lbs)
Part Number
Weight
ATWN-10003-02
77kg (169.8lbs)
ATWN-15003-02
78kg (172lbs)
ATWN-20003-02
79kg (174.2lbs)
Model
ABPT-4207-120
ABPT-4209-120
Appendix 1 - Specifications
Tri-Athlon10K
10kVA / 10kW
208/120V or 220/127V, 50/60Hz, 3-Phase, 4-Wire Plus Ground
+25% -25% (96-150V or 102-159V) at Full Load; -40% +25% (72-150V or 76-159V) at <50% Load
Max. voltage: +10, +15, +20 or 25% (default: +20)
Min. voltage: -10, -20, -30 or -40 (default: -30)
208/120V or 220/127V, 50/60Hz, 3-Phase, 4-Wire Plus Ground
Line Mode: synchronize with input; when input frequency > ±10% (±1% / ±2% / ±4% / ±5% optional),
<1% with linear load; <3% with non-linear load
Utility to Battery: 0ms; Utility to Bypass; 0ms
Load ≤110% last 60 min, ≤125% last 10 min, ≤150% last 1 min, >150% change to bypass immediately
Load ≤110% last 10 min, ≤125% last 1 min, ≤150% last 5S, >150% shut down UPS immediately
Breaker 40A
Overload, Utility Abnormal, UPS Fault, Battery Low, etc.
Short Circuit, Overload, Over Temperature, Battery Low, Fan Fault Alarm
USB, RS-485, Parallel Port, Coupler Dry Contact, Battery Temperature Sensor,
Intelligent Slot for Optional SNMP Card, Relay Card
-25⁰C ~ 55⁰C / -13⁰ F ~ 131⁰ F (no batteries)
<1500m / 4500ft. When > 1500m / 4500ft, lower the rated power for use
<55dB from 1m
UL 1778, IEC/EN 62040-1, IEC/EN 60950-1
FCC Part15:2015, IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4,
IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Standard Unit w/ Internal Batteries
Dimension
(WxHxD)
250 x 868 x
900mm
9.8 x 34.2 x 35.4in
Standard Unit w/o Internal Batteries
Dimension
(WxHxD)
250 x 868 x
900mm
±120VDC / ±132VDC /
9.8 x 34.2 x 35.4in
External Battery Pack
Weight
260kg (573.2lbs)
261kg (575.4lbs)
Tri-Athlon15K
15kVA / 15kW
40-70Hz
0.99 (40% linear load)
<2% (100% non-linear load)
Supported
± 1%
1.0
output (50/60 ±0.1% Hz).
Battery Mode: (50/60 ±0.1% Hz)
3:1
Up to 94%
Breaker 63A
0⁰C ~ 40⁰C / 32⁰F ~ 104⁰F
0 ~ 95% (non-condensing)
<55dB from 1m
Battery DC Voltage
±120Vdc
Battery DC Voltage
±96VDC / ±108VDC /
±144VDC
35
Tri-Athlon20K
20kVA / 20kW
Breaker 80A
<58dB from 1m
Built-in
Internal Battery
Charger
Quantity
1.35A*
20pcs 12V/9Ah
2.70A*
40pcs 12V/9Ah
4.05A*
60pcs 12V/9Ah
Built-in
Internal Battery
Charger
Quantity
20A*
N/A
Dimensions (WxHxD)
250 x 868 x 900mm
9.8 x 34.2 x 35.4in
Max. Qty
60
60
60
Max. Qty
N/A

Advertisement