GE PanaFlow XMT1000 User Manual page 71

Panametrics liquid flow ultrasonic transmitter
Table of Contents

Advertisement

D.2.4 FISCO [Fieldbus Intrinsically Safe Concept] (cont.)
Note: The XMT1000 FISCO control drawing is GE drawing #752-584. Please consult the factory for a copy of the
drawing.
Attention! The FISCO cover must be installed to comply with FISCO guidelines.
IMPORTANT: The FISCO cover on the XMT1000 terminal PCB is required to provide a barrier between IS and non-IS
connections. This cover must be installed if the Fieldbus application is FISCO.
The FISCO cover should come installed from the factory, as shown in Figure 21 below. The Fieldbus cables should be
installed through the XMT1000 upper right port for direct entry into the FISCO zone on the terminal PCB.
PanaFlow™ XMT1000 User's Manual
Mounting Screw
(p/n 412-2884)
Cover (p/n 421-4378)
Figure 21: Installed FISCO Cover and Mounting Screw
Appendix D. Foundation Fieldbus Communication
Cable Port
59