Appendix A. Specifications
A.2 Electronics
Enclosure
Standard: Epoxy-coated aluminum weatherproof 4X/IP66
Class I, Div 1, Groups B, C & D, Flameproof II 2 G Ex d IIC T5/T6
Optional: Stainless steel
Dimensions (Standard)
Weight: 10 lb (4.5 kg)
Size (h x d): 8.2 in. x 6.6 in. (208 mm x 168 mm)
Paths
1, 2 or 3 paths
Display
128 x 64 mono-color LCD display, configurable for single or dual measurement parameters
Display Languages
English
Keypad
Built-in magnetic, six-button keypad, for full functionality operation
Inputs/Outputs
Standard: one analog output**, one digital output*, service/Modbus (RS485)
Optional: one analog output** with HART
*Digital outputs are programmable as either pulse or frequency outputs
**Analog outputs are NAMUR NE43 compliant
Power Supplies
Standard: 100-240 VAC (50/60 Hz)
Optional: 12 to 28 VDC
Power Consumption
15 Watts maximum
Wiring Connection
Conduit entries include 6 x 3/4" NPT and 1 x 1/2" NPT on bottom, consult GE for available adapters