  • Page 1 SG-gateway Extended Version USER MANUAL 4.01.0402.20000 1.6 en-US ENGLISH...
  • Page 2 Important User Information Disclaimer The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability for any errors that may appear in this document. HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development.
  • Page 3: Table Of Contents

    Table of Contents Page User Guide ........................... 3 Target Audience.......................3 Related Documents ......................3 Document History ......................3 Conventions........................4 Safety Instructions ......................5 General Safety Instructions ....................5 Intended Use........................5 Scope of Delivery ........................ 5 Product Description ......................6 Installation........................... 7 System Requirements .......................7 Wireless via 3G or 4G Cellular Modem (Optional) ..............8 Connecting the Device to the Computer................8 Connecting the Power Connector..................9...
  • Page 4 Operation........................... 25 Serial Interface (COM)..................... 25 Ethernet Interface ......................25 I/O Interface ......................... 26 M-Bus Interface ......................26 LEDs ..........................27 10 Technical Data ........................28 11 Support/Return Hardware....................29 11.1 Support ........................29 11.2 Return Hardware ......................29 12 Disposal..........................29 Regulatory Compliance .....................
  • Page 5: User Guide

    User Guide 3 (34) User Guide Please read the manual carefully. Make sure you fully understand the manual before using the product. Target Audience This documentation is intended for use by skilled staff who is familiar with the applicable national standards of the application field. Exclusively trained staff authorized by the operator is allowed to install, commission and maintain the device.
  • Page 6: Conventions

    User Guide 4 (34) Conventions Instructions and results are structured as follows: ► instruction 1 ► instruction 2 → result 1 → result 2 Lists are structured as follows: • item 1 • item 2 Bold typeface indicates interactive parts such as connectors and switches on the hardware, or menus and buttons in a graphical user interface.
  • Page 7: Safety Instructions

    Safety Instructions 5 (34) Safety Instructions Caution The device may only be put into service and operated by qualified personnel. Risk of interference if used with antenna (wireless)! In case of interference install device or antenna in other location. If device is connected directly to the internet (without router), the firewall must be enabled.
  • Page 8: Product Description

    Product Description 6 (34) Product Description The SG-gateway family provides communication solutions for the energy infrastructure and the energy production for energy suppliers, system integrators, energy consumers and in transportation. The SG-gateway that is available in different variants provides safe and reliable communication between energy systems, control rooms and industrial automation systems.
  • Page 9: Installation

    Installation 7 (34) Installation System Requirements The WEB-PLC software runs on any up-to-date web browser on any PC operating system. The Ixxat IP configuration tool, used to determine or configure the IP address of the device, runs on Windows. The following features are needed on the local computer for the IP configuration: •...
  • Page 10: Wireless Via 3G Or 4G Cellular Modem (Optional)

    Installation 8 (34) Wireless via 3G or 4G Cellular Modem (Optional) To use the wireless function a SIM card and an antenna must be installed and the cellular modem must be enabled. See WEB PLC Online Help Settings — Network — Cellular Modem for more information how to enable and configure the cellular modem.
  • Page 11: Connecting The Power Connector

    Installation 9 (34) Connecting the Power Connector Damaged device caused by reverse polarity or wrong power supply! Make sure that power is connected with correct polarity and that power supply is of recommended type. Device goes in into safe mode if insufficient power is supplied! Make sure to connect sufficient power supply and current consumption (see Technical Data, p.
  • Page 12: Mounting The Device

    Installation 10 (34) Mounting the Device Damage caused by overheating! Ensure adequate air circulation. Observe the recommended mounting distance. Use in dry rooms exclusively. The device is designed for installation on a grounded 35 mm DIN rail. Fig. 4 Mounting the device Recommended mounting distance: •...
  • Page 13: Factory Reset

    Installation 11 (34) Factory Reset Fig. 5 Reset the device All settings are lost when device is reset. Disconnect the device from power supply. ► ► To restore the factory settings, press and hold the Reset button (1) with a pointed object. ►...
  • Page 14: Configuration

    Configuration 12 (34) Configuration Accessing the Device Fig. 6 Ixxat IP configurator ► Connect the device to the computer (see Connecting the Device to the Computer, p. Download the Ixxat IP configurator from www.ixxat.com/sg-gw-download. ► Start Ixxat IP configurator. ► →...
  • Page 15: Accessing The Embedded Web-Plc

    Configuration 13 (34) Accessing the Embedded WEB-PLC Enter IP address of the device in use into a web browser. ► → Log in window is opened. ► Enter user name (default: ixxat) and password (default: ixxat). → Home page of the WEB-PLC is opened. Fig.
  • Page 16: Updating The Firmware

    Configuration 14 (34) Updating the Firmware The firmware is constantly improved and expanded. To configure the device, the latest firmware must be downloaded on the device. For more information about updating the firmware see WEB PLC Online Help — Update. Damaged device if ongoing firmware update is stopped or cancelled! Do not disconnect the power supply, reset the device or perform any other operations while the update is in progress.
  • Page 17 Configuration 15 (34) ► Browse for the update package with button Choose File, select the desired file and click button Start update. → Start-up directory is created on SD card. → Device is programmed with the new software. → When firmware is updated, a message is shown that includes a link to the index page. Do not disconnect the power supply, reset the device or perform any other operations while ►...
  • Page 18: Changing Password And Access Rights

    Configuration 16 (34) Changing Password and Access Rights It is possible to configure 8 different users with individual passwords and access rights, and to change the password policy. The password policy applies to all created users. For more information see WEB PLC Online Help — Settings — Settings — General — User Management. As default user the user ixxat is configured (password: ixxat).
  • Page 19: Exporting And Importing A Configuration

    Configuration 17 (34) To add additional users: ► Click button Add (2). → Window Add user is opened. ► Define a user name and a password. Define the access rights for the different device functions. ► Observe the distinction between the right to modify data or to only view data. ►...
  • Page 20: Web-Plc Editor

    WEB-PLC Editor 18 (34) WEB-PLC Editor The WEB-PLC firmware provides an editor to edit the PLC program. The editor consists of two components: a diagram to connect, view and modify the inputs and outputs of the device via function blocks and I/O mapping to map inputs and outputs directly. Creating an Application The following example application of a timer shows how to create an application in the WEB-PLC editor.
  • Page 21 WEB-PLC Editor 19 (34) ► When the cursor is over the second port release the mouse button. Fig. 11 Connecting units ► Connect the ports according to Fig. 10 Example application. → If ports with different data types are connected, the data type of the output is automatically converted to the data type of the input.
  • Page 22: Debugging

    WEB-PLC Editor 20 (34) Debugging The current state of the variables and constants in the PLC can be checked directly in the diagram view via the Live View function. Fig. 13 Live view ► Click button Editor to open the WEB-PLC editor and open tab Diagram (1). ►...
  • Page 23: Mapping I/Os

    WEB-PLC Editor 21 (34) Mapping I/Os In the WEB-PLC editor inputs and outputs can be mapped directly via a mapping table. If inputs and outputs with different data types are mapped, the type is automatically converted. Click button Editor to open the WEB-PLC editor and open tab I/O Mapping. ►...
  • Page 24: Diagnostics And Logging

    Diagnostics and Logging 22 (34) Diagnostics and Logging Event Log System events are logged to a ring buffer in RAM with timestamp, message and event type. When the ring buffer is full old events are overwritten and the event log is emptied when the device is restarted.
  • Page 25: Diagnostics Console

    Diagnostics and Logging 23 (34) Diagnostics Console The WEB-PLC provides a diagnostics console to check via various commands if the device is working correctly and to get additional information in case of issues. For detailed information about the command options see WEB-PLC Online Help — Diagnostics — Diagnostics Console via button Commands cannot be executed simultaneously.
  • Page 26: Data Logging

    Diagnostics and Logging 24 (34) For sniffing command make sure, that the SD card (minimum 200 MB free memory) is ► inserted. If the SD card memory is full, no logging data is written to the SD card. ► Configure the command options and click button Start. →...
  • Page 27: Operation

    Operation 25 (34) Operation Pins Fig. 15 Device overview CAN interface (not supported) Serial interface RS232/RS485 Power connector Micro SD slot Ethernet interface Antenna connector (only in version with modem) LED array Module Status LED (only with variants PROFINET, PROFIBUS and EtherNet/IP) Network Status LED (only with variants PROFINET, PROFIBUS and EtherNet/IP) Serial Interface (COM) The serial interface is only used for Modbus RTU.
  • Page 28: I/O Interface

    Operation 26 (34) I/O Interface Only available with the I/O device variant. Digital I/Os I/O interface 24 VDC IN I0-I3 Digital pulse input, sink Q0-Q3 Digital output, source Ground Make sure, that voltage (24 V) is applied to pin + and ground to pin - (see Connecting I/O and M-Bus Interfaces, p.
  • Page 29: Leds

    PLC in status bar of editor), see WEB-PLC-Help — Status LEDs for more information 9.5.2 Hub LED The Ixxat SG-gateway supports the use of the HMS Hub. The Hub LED indicates the status of the HMS Hub connection. For further information see WEB-PLC-Help — Status LEDs. 9.5.3 GSM LED In device variants with modems the GSM LED indicates the status of the cellular modem connection.
  • Page 30: Technical Data

    8192 I/O values, up to 1024 HMS Hub variables WEB-PLC diagram Up to 2048 function units, I/O values, HMS Hub variables and constants, IPO cycle time: 10 to 1000 ms For information about the different device variants see the Ixxat SG-gateway datasheet. 4.01.0402.20000 1.6 en-US SG-gateway User Manual...
  • Page 31: Support/Return Hardware

    29 (34) Support/Return Hardware Support/Return Hardware Observe the following information in the support area on www.ixxat.com: • information about products • FAQ lists • installation notes • updated product versions • updates 11.1 Support For problems or support with the product request support at www.ixxat.com/support. ►...
  • Page 32 This page intentionally left blank...
  • Page 33: Regulatory Compliance

    Appendix A: Regulatory Compliance 31 (34) Regulatory Compliance Compliance (CE) The product is in compliance with the following EU directives: • 2014/30/EU (EMCD) • 2014/35/EU (LVD) • 2011/65/EU and delegated directive 2015/863/EU (RoHs) • device variant with modem: 2014/53/EU (RED) More information and the Declaration of Conformity can be found on www.ixxat.com Conformity...
  • Page 34: Disposal And Recycling

    Appendix A: Regulatory Compliance 32 (34) Disposal and recycling You must dispose of this product properly according to local laws and regulations. Because this product contains electronic components, it must be disposed of separately from household waste. When this product reaches its end of life, contact local authorities to learn about disposal and recycling options, or simply drop it off at your local HMS office or return it to HMS.
  • Page 35: Bul Ordinary Locations (Ord.loc.)

    Open Source Software The software of the Ixxat SG-gateway contains software components that are licensed as Free Software or Open Source Software by the rights holders. The corresponding licenses are available on the support area of the SG-gateway on www.ixxat.com. (Included in Firmware Download Package as well as included in Offline Help Package).
  • Page 36 last page © 2020 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden info@hms.se 4.01.0402.20000 1.6 en-US / 2020-02-12 / 17139...