Rotating The Connector For 1Fk7Xxx5 And 1Fk7Xxx-7 - Siemens 1FK7 Series Operating Instructions Manual

Synchronous motor
Hide thumbs Also See for 1FK7 Series:
Table of Contents

Advertisement

Connecting
6.1 Electrical connection
6.1.4

Rotating the connector for 1FK7xxx5 and 1FK7xxx-7

Power connectors and signal connectors can be rotated to a limited extent. A suitable socket
connector can be used to rotate the angle plug. Make sure that the socket connector is
completely secure to avoid damaging the pin contacts. For encoders with integrated Sensor
Modules (DQI) the cable outlet towards the top is fixed and cannot be changed.
NOTICE
Rotating the connectors
 It is not permissible that the specified rotation range is exceeded.
 In order to guarantee the degree of protection, max. 10 revolutions are permissible.
 Connectors should be rotated using the matching mating connector located on the
Table 6- 3
Connectors
Power connector, size 0.5
Power connector, size 1
Power connector, size 1.5
Signal connector (without DRIVE-CLiQ)
Signal connector (with DRIVE-CLiQ)
Figure 6-4
32
connector thread. Only rotate Sensor Modules by hand. The use of pipe wrenches,
hammers, or similar is not permitted.
Direction of rotation and max. torque when rotating
Ability to rotate the connector using 1FK7⃞⃞⃞-5 motors as an example
Rotation range
270°
270°
270°
230° for SH 20
180° for SH 28 ... 80
90° for SH 100
270°
Operating Instructions, 03/2011, 610.40700.40c
Max. torque when
rotating
8 Nm
12 Nm
20 Nm
8 Nm
12 Nm
12 Nm
8 Nm
Synchronous Motors 1FK7