Rotating The Connector On The Motor - Siemens SIMOTICS S-1FK2 Operating Instructions Manual

Synchronous motors for sinamics s120
Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Connecting
6.3 System integration
6.3.1.2

Rotating the connector on the motor

You can rotate power connectors and signal connectors within a limited range of angles.
Use a suitable socket connector to rotate the angle plug.
Unscrew and open the socket connector completely to avoid damaging the pin contacts.
Note
Rotating the connectors
• Do not exceed the permissible range of rotation.
• To ensure the degree of protection, do not rotate more than 10 times.
Rotatability of the power connector and signal connector
Table 6- 3
Motor
1FK2❑03
1FK2❑04
1FK2❑05
1FK2❑06
1FK2❑08
1FK2❑10
56
Rotation range of the power connector
Connector size of
Angle α
the power connector
M17
M23
M40
Angle α'
205
29
205
25
228
35
222
40
222
46
222
55
228
48
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 06/2019, A5E46089564B AB