Features The ES-S6A can be used either as an additional siren connected to your alarm system or as an independent siren connected to a remote control and/or wireless detectors. Wireless connection for an easy installation Radio-frequency security of the accessories: more than one million of codes...
When the alarm of your system is triggered, the ES-S6A rings out and its LEDs switch on. The ES-S6A can also be used as a standalone siren and can be connected to wireless sensors and/or to a remote control.
Power on / off Power on The siren is powered off as per default settings. Plug the siren to a 110-220V socket. You hear a long beep: the siren is on. You can also turn the siren on by long pressing (6 seconds) the Power button on the siren.
Page 5
If the siren is used as an additional siren, it must be registered to your alarm’s control panel. If the alarm is triggered, the ES-S6A will ring out and its LED lights will turn on. Register the ES-S6A in the control panel Press the Connect button on the siren.
Page 6
Use as a standalone alarm system Before using the ES-S6A as a standalone alarm system, it must be connected to a remote control or an accessory (e.g. motion detector, door / window contact). When the system is armed, if a sensor is triggered, the siren will ring out and the LED lights will turn on.
Page 7
Test a) Test the connection to a remote control Press the “Arm” button on the remote control. The siren beeps once: the connection of the remote control is successful. If not, the connection has failed, try registering the remote control again. b) Test the connection to a wireless sensor Arm the system.
Entry / Exit Delay A delay before activation can be set for the siren if the sensor is assigned to the Delay Zone*. If the Entry / Exit Delay is activated, the siren beeps once every second until the system is armed, during the period of delay set. If one of your system’s sensors triggers the alarm, the ringing out of the siren will be delayed accordingly.
Page 9
For more information, refer to the manual of your alarm system. Night Lamp mode When used as a standalone alarm system, the ES-S6A can also be used as an LED night lamp. Press the “Home Mode”...
Specifications Power supply Radio frequency 110-220V 433MHz (±75KHz) Volume Housing material 90dB ABS plastic Backup battery Operating conditions 4.2V / 600mA Lithium Temperature: -10°C ~ +55°C Relative Humidity: ≤80% (non- Static current condensing) < 13mA Dimensions Alarm current 81 x 80 x 76 mm <...
Page 11
Standards This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities.
Page 13
This user manual is available in other languages at www.etiger.com/eu/support ETIGER EUROPE Rue de la Loi, 25, 7100 La Louvière, Belgium service@etiger.com...