FEATURES

Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS value (V
123
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current measurement from 0.1mA to 1000A, capable of analyzing IT standby power consumption
to the maximum demand of a factory
Display of 35 Parameters in One Screen (3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD KW, MW, KVA, MVA) with Programmable Period
Harmonic Analysis (V
Display of 50 Harmonics in one Screen with Waveform
Display of Waveform with Peak Values (1024 Samples / Period)
Analysis of Total Harmonic Distortion (THD-F)
Graphic Phase Diagram with 3 Phase System Parameters
Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
DIP, SWELL, and OUTAGE are included in transient events.
3 Phase Voltage or Current Unbalanced Ratio (VUR, IUR)
3 Phase Voltage or Current Unbalanced Factor (d0%, d2%)
Calculated Unbalanced Current through Neutral Line (In)
512K Memory with Programmable Interval (Sampling time from 2 to 6000 seconds, data logging
time from 4.7 hours to 1180 days for 3P4W system)
Output of Waveform, Power Parameters and Harmonics on Command
Large Dot Matrix LCD Display with Backlight
Optical Isolated RS-232C Interface
and I
)
123
th
and I
) to the 99
Order
123
123
5