A9 - LONGITUDINAL STABILITY LIMITER AND WARNING DEVICE
- These tests are essential for checking the correct operation and adjustment of the different components of the device.
- Place the lift truck on flat, level ground with the wheels straight.
Use the test button
If in doubt during the test procedure, exit cleanly by short pressing the "BUCKET" MODE
Long press on the test button.
STAGE
1
1
- An audible beep.
- First green led flashing.
- Test button lit.
2
STAGE
2
1
- First green led continuously lit.
- Second green led flashing.
- Test button lit.
3
STAGE
2
3
1
- First
and
second
continuously lit.
- Third green led flashing.
- Test button lit.
STAGE
4
- The fault warning light remains
permanently on until the error
is repaired.
only when requested to do so, performing short presses (less than 1 second) and long presses (5 seconds) as instructed.
- Place the lift truck without any
attachment, with the jib fully retracted
and raised.
- Lower the jib with the engine running
at full revs and the hydraulic control
at the maximum setting. Lowering
slows until movement is cut-off.
- Lower the jib until the movement
is cut-off.
- Request the following, in order:a
reverse tilt, a forward tilt (dumping)
and a telescope extension. None
green
leds
of these 3 movements should
be possible.
- The fault indicator
- Press the button
- If there are several error codes, press the button
error codes.
NOTE: A defective fuse can generate several error codes. If this is the case, check the fuses
(see: 2 - DESCRIPTION: 11 - FUSES AND RELAYS IN THE CAB)
- If error code"
limiter and warning device (see: 3 - MAINTENANCE: G - OCCASIONAL MAINTENANCE).
- Contact your dealer, stating the error code or error codes (see following table).
NOTE: For the stage 3 test, specify the non-conforming aggravating hydraulic movements, if necessary.
Short
press
the test
button.
Short
press
the test
button.
Short
press
the test
button.
and a beep indicate a fault.
briefly to view the error code.
A7
A6
A4
A3
is displayed", the problem may be resolved by resetting the longitudinal stability
3-17
or "SUSPENDED LOAD" MODE button
TEST OK
- One audible beep and progresses
to stage 2.
TEST NOT OK
- Two audible beeps and lighting of the fault
warning light
.
- Exit test mode.
- Go to stage 4.
TEST OK
- One audible beep and progresses
to stage 3.
TEST NOT OK
- Two audible beeps and lighting of the fault
warning light
.
- Exit test mode.
- Go to stage 4.
TEST OK
- Conformity of aggravating movement
cut-off.
- Exit test mode. All the LEDs will light
for 2 seconds and an audible beep will
be sounded.
TEST NOT OK
- Fault warning light comes on
- Exit test mode.
- Go to stage 4.
briefly several times to loop through the
CHECK
.
.

Hide quick links: