Electrical Maintenance - Led Indicator Checks - Motorola McIAS 1610 Series System Manual

Table of Contents

Advertisement

1.2

Electrical Maintenance - LED Indicator Checks

McIAS 1610 utilizes light emitting diode (LED) indicators on the SBC, telephony
interface and the Power Supply boards to signify specific system functions. If an LED
(other than Internal Signal Battery) on the Power Supply board is not lit, a voltage
problem exists. The board must be pulled and replaced.
McIAS 1610 LEDs are described in Table 1-1 below.
LED
LOCATION
SBC
(McIAS 1610/68)
Slot 5
SBC
(McIAS 1610/IP)
Slot 5
Power Supply
Board
Slot 1
LED
LED
COLOR
NAME
Red
FAIL
Yellow
STATUS
Green
RUN
Green
SCON
Red
FAIL
Yellow
STAT
Green
RUN
Green
SCON
Green
LAN
Green
+12V (LAN)
Green
SCSI
Green
VME
FRAME
Green
BATTERY
SIGNAL
Green
BATTERY
Green
-12v
Green
+12v
Green
+5v
Table 1-1 (Part 1)
LED Indicator Functions
DESCRIPTION WHEN LIT
Indicates system reset. Cleared by firmware
upon successful SBC initialization.
When fully lit, the processor has halted.
Indicates SBC is in operation.
Indicates that the SBC is the VME BUS
system controller.
Indicates system reset. Cleared by firmware
upon successful SBC initialization.
When fully lit, the processor has halted.
Indicates SBC is in operation.
Indicates that the SBC is the VME BUS
system controller.
Indicates that the LAN chip is enabled.
Indicates that power is available to the Ethernet
transceiver interface.
Indicates that the SCSI chip is enabled.
Indicates VMEbus activity.
-48 volt input power. (Fuse F1 is functional.)
-48 volt input power. (Fuse F2 is functional.)
3 LEDs to indicate the output from the
Power Supply to drive the rest of the
system.
2