Yamaha Tenere 700 2020 Service Manual page 444

Table of Contents

Advertisement

Turn signal/hazard relay output
voltage
DC 12V
a. Connect the digital circuit tester to the turn
signal/hazard relay terminal as shown.
Digital circuit tester (CD732)
90890-03243
Model 88 Multimeter with ta-
chometer
YU-A1927
• Positive tester probe
brown/white "1"
• Negative tester probe
Ground
b. Turn the main switch to "ON".
c. Measure the turn signal/hazard relay out-
put voltage.
EAS30555
CHECKING THE DIODE
1. Check:
• Diode
Out of specification → Replace.
Digital circuit tester (CD732)
90890-03243
Model 88 Multimeter with ta-
chometer
YU-A1927
Continuity
Positive tester probe
red/black "2"
Negative tester probe
red "1"
No continuity
Positive tester probe
red "1"
Negative tester probe
red/black "2"
ELECTRICAL COMPONENTS
a. Disconnect the diode from the wire har-
ness.
b. Connect the digital circuit tester to the di-
ode terminals as shown.
c. Check the diode for continuity.
d. Check the diode for no continuity.
EAS30795
CHECKING THE RELAY UNIT (DIODE)
1. Check:
• Relay unit (diode)
Out of specification → Replace.
Digital circuit tester (CD732)
90890-03243
Model 88 Multimeter with ta-
chometer
YU-A1927
8-133
1
R
R/B
2

Advertisement