About this document
1.1
Applicable Documents
All available documents for the product è www.festo.com/sp.
2
Safety
2.1
General safety instructions
Only use the product in original status without unauthorised modifications.
Only use the product if it is in perfect technical condition.
Only use media in accordance with the specifications è Technical data.
Observe labelling on the product.
Note that changes to the switching status (EDIT mode) become effective
immediately.
2.2
Intended use
The product is intended for monitoring the pressure of compressed air and inert
gases in the piping.
2.3
Training of qualified personnel
Work on the product should only be conducted by qualified personnel.
3
Service
Contact your regional Festo contact person if you have technical questions
è www.festo.com.
4
Product overview
4.1
Function
The sensor converts pneumatic pressure values (relative pressure) into electrical
signals, which can be used for control or regulating functions. Measurements are
carried out using a piezoresistive sensor element with a downstream electronic
evaluation unit. The connection to the higher-level system is established via a
switching output.
The switching output can be configured to monitor a threshold value or a pressure
range. The PNP or NPN and the normally open (N/O) or normally closed (N/C) out-
put can be optionally set in this process.
4.1.1
Operating statuses
Operating status
Function
RUN mode
Basic status after the operating voltage is switched on
Display of the current measured value
SHOW mode
Display of the current settings
EDIT mode
Setting or modification of parameters
TEACH mode
Acceptance of the current measured value to determine
switching points
Tab. 1
4.1.2
Threshold value comparator for monitoring of a pressure threshold _|¯
Function
Switching function:
1 switching point (SP)
TEACH mode:
Festo SE & Co. KG
2 teach points (TP1, TP2)
Ruiter Straße 82
SP = ½ (TP1+TP2)
73734 Esslingen
Germany
+49 711 347-0
Tab. 2
www.festo.com
Window comparator for monitoring of a pressure range _|¯|_
Function
Switching function:
2 switching points (SP.Lo,
SP.Hi)
8140082
TEACH mode
2 teach points (TP1, TP2)
TP1 = SP.Lo, TP2 = SP.Hi
1) SP.Lo = lower pressure/vacuum value, SP.Hi = higher pressure/vacuum value, dependent on the Teach
sequence
Tab. 3
4.2
4.2.1
1 Display
2 A pushbutton
3 EDIT pushbutton
Fig. 1 Product design
5
5.1
NOTICE!
An unfavourable mounting position may impair the function of the product.
Mount the sensor so that condensation from the compressed air lines cannot
accumulate in the device.
Install the sensor so that it cannot be heated above the maximum permissible
operating temperature (plan for convection possibilities).
Remove all transport packaging. The material used in the packaging has been
specifically chosen for its recyclability.
Avoid applying force to the sensor housing during mechanical and pneumatic
assembly.
SPAN-B-...-G18M/R18M
Seal connecting thread.
Fig. 2 Example with G18M
Switching functions
N/O (normally open)
Out
HY
1
0
SP
TP1
N/O (normally open)
Out
HY
1
1)
:
0
TP1=SP.Lo TP2=SP.Hi
Configuration
Product design
Installation
Mechanical and pneumatic
N/C (normally closed)
Out
HY
1
0
p
SP
TP1
TP2
TP2
N/C (normally closed)
Out
HY
HY
HY
1
0
p
TP1=SP.Lo TP2=SP.Hi
4 B pushbutton
5 Pneumatic port
6 Electrical connection
p
p

Advertisement

loading

Summary of Contents for Festo SPAN-B Series

  • Page 1 1) SP.Lo = lower pressure/vacuum value, SP.Hi = higher pressure/vacuum value, dependent on the Teach sequence Translation of the original instructions Tab. 3 © 2020 all rights reserved to Festo SE & Co. KG Configuration 4.2.1 Product design About this document Applicable Documents All available documents for the product è www.festo.com/sp.
  • Page 2 Commissioning SPAN-B -...- G18FPM/M5FAL with mounting bracket – Recommendation for the variant "SPAN-B-...-G18FPM..": use type OL-1/8 LCD display sealing ring at the pneumatic connection. 1 Switching status indication 3 Pressure units 2 Main display (e.g. measurement 4 Status information value) Fig. 7 LCD display Example for LCD display Meaning Fig.
  • Page 3 Switching output OutA 3. Briefly press Edit pushbutton. 1. Press the A pushbutton. Ä [OutA] flashes. The parameter entry option is unblocked. Ä The first parameter set is displayed. [Fctn] flashes. 6.4.2 Configuring switching output 2. Press the A pushbutton to display each of the following parameters. Requirement: the sensor is ready for operation (RUN mode).
  • Page 4 Send the packaging and product for environmentally sound recycling in accord- There is no time-out in the TEACH mode. The sensor changes to the RUN mode ance with the current regulations è www.festo.com/sp. only after the entire teach process is ended.

This manual is also suitable for:

Span-b11r-g18m-pn-pn-l1Span-b11r-m5f-pn-pn-l1Span-b11r-q4-pnlk-pnvba-l1Span-b11r-q4-pn-pn-l1Span-b11r-r18m-pn-pn-l1Span-b2r-g18m-pnlk-pnvba-l1 ... Show all