5.0

Technical data

Power supply unit
Supply voltage
Slow fuse
Mains frequency
Power supply cord
Max. welding capacity
Open-circuit voltage
Welding current
Welding time**
Pulse welding time**
Ambient temperature
Type of protection
Dimensions H/W/D mm
Weight power supply unit
Dimensions of power supply
unit in trolley H/W/D in mm
Total weight inc. accessories
Spot welding tongs (pneumatic)
Weight (without cable)
Weight (with cable)
Operating pressure
Electrode arms
Electrode contact pressure
Welding cable Ø/length
Electrodes Ø
Push spot welder
Welding cable Ø /length
Earth cable Ø /length
Weight
Electrodes Ø
**Operation with a lower rating fuse at reduced power is possible.
**+ automatic correction
400 V (380-415 V)
32/35 A*
50/60 Hz
14.7 kVA
45 kVA
12 V
6400A,
3% duty cycle
0.03 – 0.9 s
automatic
adjustment
0.1 – 1.5 s
automatic
adjustment
40° C
IP21
375/265/535
54.5 kg
1020/517/600
approx. 97.1 kg
3.5 kg
11.5 kg
8 bar
20 x 20 mm
1800 N
120 mm²/2.5 m
12 mm
120 mm² / 2.2 m
120 mm / 1.5 m
6.15 kg
10 mm
- 9 -
230V (190-240 V)
63 A*
50/60 Hz
14.7 kVA
45 kVA
12 V
6400A,
3% duty cycle
0.03 – 0.9 s
automatic
adjustment
0.1 – 1.5 s
automatic
adjustment
40° C
IP21
375/265/535
54.5 kg
1020/517/600
approx. 97.1 kg
3.5 kg
11.5 kg
8 bar
20 x 20 mm
1800 N
120 mm²/2.5 m
120 mm² / 2.2 m
120 mm / 1.5 m
6.15 kg
10 mm