M+CameraRecord_AXIS_EventTrigger_R (Pre- and Post-trigger recording)
■Local label
■Program
Label name
Setting value
i_uConnectionNo
1
i_sUsername
"User1234"
i_sPassword
"Pass1234"
i_uVirtualInputPortNo
9
When bEventTrigger_EN (FB execution command) is turned on, the recording is instructed to the network camera.
• The network camera is specified with i_uConnectionNo (Connection number).
• The network camera authentication is cleared with i_sUsername (User name) and i_sPassword (Password).
• A recording event specified with i_uVirtualInputPortNo (Virtual input port number) is executed.
Description
Sets the connection number to 1.
Sets the user name to "User1234".
Sets the password to "Pass1234".
Sets the virtual input port number to 9.