• For M+CameraRecord_AXIS_EventTrigger_R (Recording direction)
This FB is executed at the timing of recording to execute a recording event of the network camera.
i_bEN
OFF
o_bOK
OFF
Virtual input port status of
OFF
the camera
Recording duration
OFF
(1) Video recording duration
(2) Pre-trigger recording time (Prebuffer)
(3) Post-trigger recording time (Postbuffer)
Input label
i_bEN
i_uConnectionNo
i_sUsername
i_sPassword
i_uVirtualInputPortNo
Output label
o_bENO
o_bOK
o_bErr
o_uErrId
• Do not start the second video recording until the post-trigger recording period (Postbuffer) ends.
• If recording events occur consecutively in a brief period of time and the recording duration of one event
overlaps the recording duration of the subsequent event, this FB may not be completed successfully and a
timeout error (C1E2H) may occur. Ensure that the recording durations of events do not overlap when this
FB is executed.
ON
OFF
ON
ON
OFF
ON
OFF
OFF
(2)
(3)
(1)
Setting details
Connects with a device used as a recording trigger.
On: The FB is activated (a recording event is executed).
Off: The FB is stopped.
Sets the connection number.
Sets the user name registered in the network camera.
Sets the password registered in the network camera.
Specifies the port number of the virtual input for the recording event registered in the network camera.
Setting details
On: The execution command is on.
Off: The execution command is off.
The on state indicates that the virtual input port status on the network camera side has been switched.
The on state indicates that an error has occurred in the FB.
Returns the error code of an error occurred in the FB.