External device configuration
Set the network camera to be connected.
[Navigation window]  [Parameter]  Programmable controller  [Module Parameter]  [Basic Settings]  [External
Device Configuration]
1.
From "Module List", select "Active Connection Module" and drag and drop it to "List of devices" or "Device map area".
2.
For the selected "Active Connection Module", configure the following.
• Communication Method (Socket Communication)
• Port No. of PLC (any number from 1 to 4999 and 5010 to 65534)
• IP Address of Sensor/Device (IP address of the network camera)
• Port No. of Sensor/Device (80)
• Existence Confirmation (KeepAlive)
If the port number has been changed on the network camera side, set the changed value to "Port No." of
"Sensor/Device".
3.
Click the [Close with Reflecting the Setting] button and click the [Apply] button in the module parameter.
4 INSTALLATION AND SETTINGS
4.2 Ethernet Port Settings