Mitsubishi Electric MELSEC iQ-R Series User Manual page 32

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Creating a program
Create a program using an FB.
1.
From "Library" on the "Element Selection" window, drag and drop the applicable FB to the editor.
2.
Enter the input labels and output labels of the created FB.
• For M+CameraRecord_AXIS_SetTime_R (Time setting)
This FB is executed once when the operating status of the CPU module is changed to RUN to set the time information of the
CPU module to the network camera.
Input label
i_bEN
i_uConnectionNo
i_sUsername
i_sPassword
Output label
o_bENO
o_bOK
o_bErr
o_uErrId
4 INSTALLATION AND SETTINGS
30
4.4 Creating a Program
Setting details
On: The FB is activated.
Off: The FB is stopped.
Sets the connection number.
Sets the user name registered in the network camera.
Sets the password registered in the network camera.
Setting details
On: The execution command is on.
Off: The execution command is off.
The on state indicates that setting the time has been completed.
The on state indicates that an error has occurred in the FB.
Returns the error code of an error occurred in the FB.