7.2

M+CameraRecord_AXIS_EventTrigger_R

Overview

This FB executes the recording event set to the network camera manufactured by Axis Communications that is connected to
the MELSEC iQ-R series CPU module.
M+CameraRecord_AXIS_EventTrigger_R
(1)
B:i_bEN
(2)
DUT:i_uConnectionNo
S:i_sUsername
(3)
(4)
S:i_sPassword
(5)
UW:i_uVirtualInputPortNo

Labels

Input labels
No.
Variable name
Name
(1)
i_bEN
Execution command
(2)
i_uConnectionNo
Connection number
(3)
i_sUsername
User name
(4)
i_sPassword
Password
(5)
i_uVirtualInputPortNo
Virtual input port
number
Output labels
No.
Variable name
Name
(6)
o_bENO
Execution status
(7)
o_bOK
FB completed
successfully
(8)
o_bErr
FB completed with
an error
(9)
o_uErrId
Error code
o_bENO:B
(6)
(7)
o_bOK:B
o_bErr:B
(8)
o_uErrId:UW
(9)
Data type
Effective
range
Bit
On or off
Word [unsigned]
1 to 16
String (255)
4 to 14
characters
String (255)
4 to 64
characters
Word [unsigned]
1 to 32
Data type
Initial
value
Bit
OFF
Bit
OFF
Bit
OFF
Word [unsigned]
0
Description
On: The FB is activated.
Off: The FB is not activated.
Specifies the connection number.
Specifies the user name registered in the corresponding
network camera.
(Available strings: a to z, A to Z, 0 to 9)
Specifies the password registered in the corresponding
network camera.
Specifies the port number of the virtual input for which the
recording event is executed.
Page 20 Recording event settings
Description
On: The execution command is on.
Off: The execution command is off.
The on state indicates that sending the command for
switching the virtual input port has been completed.
The on state indicates that an error has occurred in the FB.
The error code of an error occurred in the FB is stored.