CV table
CVs may be used with Loco Address (L), switch address (S) or both (LS)
CV
Description
71 PWM for SW1 (A1+A2)
75 switch time opposite direction 1
76 switch time opposite direction 1
255 Decoder type
Attachment 1: (CV 51, 52) – Special functions A1 + A2
Value
0
Continuous Operation
1..15
Continuous Symmetric Flashing
Inverse Coupling with output F1
16
(Alternating flashing)
+32
increase time base to 2.0 sec.
Short Term Function, Monoflop
+64
(Time Base 0,25 sec per unit)
+ 128
Asymmetrical Flashing (1/3 ON – 2/3 OFF)
+192
Asymmetrical Flashing (2/3 ON – 1/3 OFF)
Attachment 2: Default values at reset
Resetvalue
11
1
17
3
16
15
16
242 242
22
41
42
1
Application
18
29
31
0
128 128
0
51
52
61
2
67
67
1
D L/W Range
15 LW
0...15
15= full voltage
0
LW
0=off
0...255
1...255 = time basis 0,25 sek
0
LW
242
---
read only
if both 0 = state storage
(Time Base 0,25 sec per unit)
only in CV 52 (F2 to F1)
(Loco address mode only)
Only with symmetric flash + Monoflop
switches after reaching the time limit
Standard Switch Function
Loco address mode only
Loco address mode only
32
1
62
71
75
76
1
15
0
0
Note
Note
19
Need help?
Do you have a question about the DiMAX 1-Channel Switch Decoder II and is the answer not in the manual?
Questions and answers