Webasto Live Installation Instructions Manual page 41

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 29
Operat-
Description
ing in-
dicator
N1
When the charging station is
switched on, this lights up red for
30 s, then flashes red-green-blue at
one-second intervals. A beep sounds
if the start-up process is successful.
N2
LED is blue:
Charging station in standby mode;
charging station can be used.
N3
LED is green:
Charging station being used; char-
ging vehicle.
N4
LED flashes blue at 1 second intervals:
Charging coupling connected to the
vehicle, authentication has not been
carried out yet.
N6
LED flashes green at 1 second inter-
vals:
Charging cycle paused by the vehicle
(indicator in configuration can be ac-
tivated)
Indicator lamps
Table 2:
7.1.2 Fault conditions
See also Fig. 9
Fault
Description
list
F1
LED is yellow for 1 s and green for 2 s:
The charging station has become hot
and charges the vehicle with reduced
5110326C_OI-II_Webasto Live
Fault
Description
list
power. After a cool-down phase the
charging station continues the normal
charging cycle.
F2
LED is yellow and an acoustic signal
sounds for 0.5 s:
Excess temperature. Charging stopped
due to high temperature within the
charging station. After a cool-down
phase the charging station continues
the normal charging cycle.
F3
LED is red and an acoustic signal
sounds for 0.5 s and then for 5 s fol-
lowing a pause:
There is a problem in the voltage or sys-
tem monitoring.
Fault indicators and troubleshooting
Table 3:
DANGER
Danger of fatal electric shock.
Switch off and secure the power
u
supply to the charging station.
Only then unplug the cable from
the vehicle.
Contact the Webasto Charging
u
Hotline at 00800-24274464.
Fault
Description
list
F5
LED flashes red for 1 s at 2 s intervals
and an acoustic signal sounds for 0.5 s
and then for 5 s following a pause:
There is a fault in the vehicle.
Fault
Description
list
u
Re-connect the vehicle
u
If the warning persists, contact
the car customer service.
F6
LED flashes red 2 times, followed by a
brief pause and a buzzer sounds for 0.5
s:
The supply voltage is outside the valid
range of 180 V to 270 V.
u
Checking by an authorised elec-
trician.
F7
LED flashes red 3 times, followed by a
brief pause and a buzzer sounds for 0.5
s:
There is a fault in the installation. Info
for installer.
Fault indicators and troubleshooting
Table 4:
7.1.3 Communication statuses
See also Fig. 10
Operat-
Description
ing in-
dicator
C1
LED is blue at 0.5 second intervals:
The authorisation process is in pro-
gress.
C2
LED lights up red for 1.5 / 1 / 0.5 s
and a beep sounds at the same time:
Restart of the charging station by
RFID dongle owner/operator (indic-
ator in configuration can be activ-
ated)
EN