In PRESET mode the MAGICFX
operational addresses.
DMX Address
Safety address
Start address (Preset)
Start address + 1 (Speed)
Start address + 2 (Direction) 3 – 511
Start address + 3 (Go)
The Safety address cannot be the same as one of the operational addresses.
Operating of the addresses in PRESET mode results in the following:
DMX Address
Safety address
Start address
(Preset)
Start address + 1
(Speed)
PSYCO2JET is controlled with 1 safety address and 4
®
Address range
1 – 512
1 – 509
2 – 510
4 – 512
DMX addresses in PRESET mode
DMX Value (decimal)
0
99
100
155
156
255
0
24
25
49
50
74
75
99
100
124
125
149
150
174
175
199
200
224
225
255
0
255
MAGICFX
Result
Device disabled
Device enabled
Device test mode (CO2 output is
disabled)
#1: Single pulse straight up (0°)
#2: 2 pulses distributed over 180° (-45°
+45°)
#3: 3 pulses distributed over 180° (-90°,
0°, +90°)
#4: 4 pulses distributed over 180° (-90°,
-30°, +30°, +90°)
#5: 5 pulses distributed over 180° (-90°,
-45°, 0°, +45°, +90°)
#6: Random pulses over 180°
#7: Pulse at +45°, pulse at -45°, pulse
at +45°, sweep from -45° back to +45°
#8: Three sweeps over 180° (-90° to
-54°, -18° to +18° and +54° to +90°)
#9: Pulse at -90°, pulse at +90°, pulse
at -60°, pulse at +60°, pulse at -30°,
pulse at +30°, long pulse at 0°
#10: Sweep over 180°
Minimal speed -> Full speed