Advertisement

USER AND INSTALLATION MANUAL
ENGLISH
STAGE, STADIUM
& X-TREME SHOT.
CONFETTI & STREAMER FX
PART01339
rev 01-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STAGE SHOT II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MAGIC FX STAGE SHOT II

  • Page 1 USER AND INSTALLATION MANUAL ENGLISH STAGE, STADIUM & X-TREME SHOT. PART01339 CONFETTI & STREAMER FX rev 01-00...
  • Page 2: Disclaimer

    Any brand names mentioned in this manual are registered trademarks of their respective owners. LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use, use other than that stated in this manual, and use other than in accordance with the General Conditions registered at the Chamber of Commerce.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Disclaimer Trademarks Liability Foreword Language Revision table Meet the MAGICFX STAGE SHOT II, STADIUM SHOT II ®   & X-TREME SHOT!  1.1  Main parts  MAGICFX STAGE SHOT II ® MAGICFX STADIUM SHOT II ® MAGICFX  X-TREME SHOT  ® 2  Shoot safely!  2.1  General safety rules  2.2  Transport ...
  • Page 4: Foreword

    FOREWORD Congratulations! You have bought a great new product from MAGIC FX. This manual contains all information required for the intended use of the equipment. Deviation from the described intended use can result in a hazardous situation and/or property damage.
  • Page 5: Stage Shot Ii, Stadium Shot Ii

    ®   & X-TREME SHOT! The MAGICFX STAGE SHOT II is a special effects machine that shoots confetti loads up to 1 kg 10 ® meters far* and 12 polybags of streamers 20 meters far*. The MAGICFX STAGE SHOT II is equipped ®...
  • Page 6: Magicfx ® Stage Shot

    MAGICFX STAGE SHOT II ® TECHNICAL DATA Product Product Name MAGICFX STAGE SHOT II ® Product Code MFX0410II Product Type CONFETTI & STREAMER FX Main Length (mm/in) 23,2 Dimensions Width (mm/in) 17,7 Height (mm/in) 29,5 Weight Empty weight (kg/lb) 156,5 Environment Minimum Temperature (ºC/ºF)
  • Page 7: Magicfx ® Stadium Shot

    INPUT & OUTPUT The output pipe has a capacity of 15 liters and can be filled with confetti or streamers. The maximum load per blast depends on the type of input material. The output distance depends on the type of input material and the load. The output has a maximum distance of 25 m. Wind and other weather circumstances will influence the output distance.
  • Page 8: Magicfx ® X-Treme Shot

    ACCESSORIES Code Product MFX0404 Compression caps tape 50m X 50mm MFX0416 Cover for the MAGICFX STADIUM SHOT II ® MFX0407 25 caps + 25 cores for the MAGICFX STADIUM SHOT II ® MFX0406II Flexible air hose 5m II MFX0405 Air Compressor 8L / 8Bar Accessories of the MAGICFX STADIUM SHOT II ®...
  • Page 9 Pressure Tank Maximum Pressure (Bar/Psi) Volume (L) Usage Consumable(s) Confetti & Streamers Technical data of the MAGICFX X-TREME SHOT ® PRODUCT IDENTIFICATION Type plate of the MAGICFX X-TREME SHOT ® ACCESSORIES Code Product MFX0404 Compression caps tape 50m X 50mm MFX0417 Cover for the MAGICFX X-TREME SHOT...
  • Page 10: Shoot Safely

    SHOOT SAFELY! The machine has been designed and constructed in such a manner that they can be used safely. This applies to the use, the circumstances and the regulations as described in this documentation. Reading this documentation and following the instructions are therefore necessary for everyone who is authorised to work with the machine.
  • Page 11: 2.5 Noise Level

    2.5  NOISE LEVEL The environmental noise level as measured at the ear is greater than 70 dB(A). This level of noise is only reached during the short instances that the output is active. Always wear hearing protection when you are within 5 meters of the machine during operation. SAFETY SYMBOLS The following safety symbols are present on the machine.
  • Page 12: Let's Shoot

    LET’S SHOOT! INSTALL THE MACHINE Bring the cased machine to the desired location. Unlock and remove the top cover. 12    MAGICFX® STAGE SHOT II, STADIUM SHOT II & X-TREME SHOT  — User and Installation Manual...
  • Page 13 Remove the output pipe. Pull the locking clamps downwards to unlock and rotate them upwards. Place the output pipe in the coupling while holding the locking clamps upwards. MAGICFX® STAGE SHOT II, STADIUM SHOT II & X-TREME SHOT  — User and Installation Manual...
  • Page 14 Lock the output pipe in place with the locking clamps. Pull the clamps outwards to check if the locking pins are properly locked in place. If not: remove the output pipe and repeat step 5 and 6. Never use the machine when the clamps are not working properly.
  • Page 15 Set the tank with attached output pipe in an angle between 0 and 90 degrees. 10 Turn the tank clamps clockwise to firmly secure the tank in position. 11 Place the machine in its final position and set the brakes. MAGICFX® STAGE SHOT II, STADIUM SHOT II & X-TREME SHOT ...
  • Page 16: Connect Power

    12 1. Create a safety zone of 2 m around the machine. 2. Make sure that the direct output will be free from persons, animals and objects. CONNECT POWER Make sure that the power output on your controller or power switch is disabled. Connect power cable(s) to the 12-24 Vdc input or the 100-250 Vac input.
  • Page 17: Run A Test

    PowerCon TRUE1 female POWER POWER IN POWER OUT Connect the other end(s) to your controller or power switch. Optionally connect another machine to the power output with a power link cable (100-250 Vac only). PowerCon TRUE1 male PowerCon TRUE1 female POWER POWER IN POWER OUT...
  • Page 18: Fill With Confetti And/Or Streamers

    Switch the power on and check if 1. the LED power indicator lights up; 2. you hear a click sound. If desired run a test with pressure. Follow the step from Section 3.5 and 3.6. FILL WITH CONFETTI AND/OR STREAMERS Make sure that the machine is functioning correctly by running a test first, see Section 3.3.. Make sure that the pressure level is zero by checking the tank pressure meter.
  • Page 19: 3.5 Fill With Pressurized Air

    Place a pressure cap on top of the output pipe. Secure the pressure cap to the output pipe with special pressure cap tape. 3.5  FILL WITH PRESSURIZED AIR Connect the hose from an air compressor to the air coupling. Only use a compressor with a maximum output of 8 bar.
  • Page 20: Let's Shoot

    LET’S SHOOT! 1. Make sure that the prescribed safety zone is free from persons and objects. 2. When it’s time to shoot, switch the power on. 3. Enjoy the view! 4. Switch the power off. CLEAN UP Disconnect the power cable(s). Disconnect the compressor hose from the air coupling (if not done already).
  • Page 21 Open the ventilation valve to remove any remaining air from the tank. TANK PRESSURE Pull the locking clamps downwards to unlock and rotate them upwards. Remove the output pipe from the coupling. MAGICFX® STAGE SHOT II, STADIUM SHOT II & X-TREME SHOT  — User and Installation Manual...
  • Page 22 Store the output pipe in the flight case Place and lock the top cover. Release the brakes. 22    MAGICFX® STAGE SHOT II, STADIUM SHOT II & X-TREME SHOT  — User and Installation Manual...
  • Page 23: Maintenance

    Do not replace parts yourself; always consult MAGIC FX. 5  TROUBLESHOOTING Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved with the instructions as described in this manual. CORRECT DISPOSAL This symbol on the product and / or accompanying documents means that used electrical and electronic products (WEEE) should not be mixed with general household waste.
  • Page 24: Ec Declaration Of Conformity

    DECLARATION OF CONFORMITY According to Annex III A Low Voltage Directive 2014/35/EU + Machinery Directive 2006/42/EC MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the product with the following specifications: Name machine : STAGE SHOT II / STADIUM SHOT II / X-TREME SHOT...
  • Page 26 WWW.MAGICFX.EU...

This manual is also suitable for:

Stadium shot iiX-treme shot

Table of Contents