UR FOG FAST 01 NEW Installation And Use Manual page 4

Table of Contents

Advertisement

4
INTALLATION TIPS TO INSTALL FOGGING SYSTEMS –
Please observe the following instructions for mounting UR Fog:
1.
2.
3.
Do not look directly into the nozzle. Do not add any other substance into the cylinders.
4.
The nozzle may reach high temperatures, touch it may cause burns.
5.
When UR Fog produces fog avoid staying closer than 1 meter from the machine.
6.
When UR Fog is armed avoid staying closer than 50 cm from the nozzle.
7.
Before testing UR Fog, remember to report it in advance to the firefighters in your area to avoid false alarms.
8.
Remember to put warning labels about the presence of UR Fog on the windows.
9.
Report its installation to the firefighters in your area and eventually to other institutions if needed.
10. It is necessary to add an external switch to separate the fog generator from the alarm system and it should be activated
before the maintenance to avoid that input tests, for example, can activate the fog generator.
11. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase the suggested minimum
distance. Thanks to the power of the jet, UR Fog reaches and exceeds more than 10 meters away in the first 3 seconds from
the point where the machine is installed.
12. Setting the shooting time interval between the minimum and maximum shown in the time table, avoid "overshooting" even
if the produced fog is dry and generally doesn't leave residue. A shot that goes far beyond the recommended seconds can
create a residue problems in the room.
13. Install at an height of about 2,5 meters not to let it be reached, avoiding possible tampering.
14. Install with a maximum inclination of 20°.
15. Do not move the machine when it is still hot.
16. The main body of UR Fog Fast line, which has the heating system enclosed inside a metal frame, should not be opened unless
by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours UR Fog has
been shut off. The internal part may reach really high temperature.
17. Do not activate the UR Fog machine before the installation is completed.
18. Insert the cylinders as the last procedure and verify the anti-tampering function.
19. When the installation is finished, always test the system.
20. From the moment of UR Fog activation, at least one hour is necessary to reach the minimum temperature needed for the fog
shooting.
21. Install UR Fog avoiding any obstacles in front of it which can prevent the spreading of the fog.
22. Request to UR Fog or its distributors to take part in courses for installers to ensure the optimal installation of the equipment.
Installation and use manual FAST 01 NEW 220V
RECOMMENDATIONS
The machine must be installed avoiding to obstruct escape routes.
Verify the fog does not limit the visibility near: stairs, landings, moving objects that
may cause: falls down, injuries or any damage to persons.