Advertisement

INSTALLATION AND USE
MANUAL
FAST 02
FAST 03
mod.
e
ENGLISH MANUAL
Installation and use manual models FAST 02 e FAST 03
rev 1.0.0 October 2013
Page 1 di 19

Advertisement

Table of Contents
loading

Summary of Contents for UR FOG FAST 02

  • Page 1 INSTALLATION AND USE MANUAL FAST 02 FAST 03 mod. ENGLISH MANUAL Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013 Page 1 di 19...
  • Page 2: Table Of Contents

    1. The machine FAST 02 or FAST 03, 2. 1 fog fluid charged cylinder for the model FAST 03 1C or two cylinders for the models FAST 03 2C and FAST 02 2C. 3. A label to indicate device presence.
  • Page 3: Introduction To The Product

    CONDITIONS OF USE AND WARNINGS The fog generated by UR Fog does not create particular problems or injuries for a human being for a short stay in a fogged room if the system is used according to the manufacturer’s recommendations. Generated fog is stated as safe for people and animals from an authorized international certification company and is proved that do not leave any residual.
  • Page 4: Installations Tips Of Fogging Systems - Recommendations

    16. Do not move the machine when it is still hot. 17. The main body of UR Fog FAST 02 and Fast 03 that has the heating system closed inside a metal frame, should not be opened unless from specific and authorized service centers. For no reason open and touch insulation before 24 hours UR Fog has been shut off.
  • Page 5: How To Activate The System

    HOW TO ACTIVATE THE SYSTEM It is always recommended to affix the Fast 02 or Fast 03 on a wall also when it is on a flat surface. Verify always that the bracket or the support surface are suitable for the weight of the machine.
  • Page 6: Technical Specifications

    IF YOU NEED TO REPLACE THE FUSE, USE THE ONE WITH EXACTLY THE SAME SPECIFICATIONS. IF ANY DOUBT, ASK YOUR AUTHORIZED DEALER Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013 Page 6 di 19...
  • Page 7: Battery Power

    The maximum current drawn from UR Fog on this input is 230 mA. Arming input Connecting this input to positive, Fast 02 or 03 is armed, blue frontal led is switched on and when the machine reaches proper temperature it means that it is ready for shooting.
  • Page 8: Connection Examples

    SHOOTS shooting input. Putting this input to positive, if Fast 02 or 03 is hot and armed, starts fog emission for the set time (see programming section shooting time) Negative reference connected to terminal 1 OUTPUTS EMPTY Output empty cylinder This output (NPN Open Collector) closes towards negative direction when at least one of the two cylinders is empty.
  • Page 9 In the diagram above Ur Fog is powered by an external power supply. When Fast 02 or 03 is used with an external power supply in case of power failure, the machine will not be able to shoot. For this reason, when the anti-robbery function must be guaranteed in the absence of power, it is needed to add a rechargeable battery with a capacity of 1.2 Ah 12V in parallel to the output of power...
  • Page 10 100mA Example of connection of UR Fog outputs with opened inputs of an alarm system The UR Fog outputs are normally opened and connected with input zones of the alarm control panel normally opened According to the diagram above: when there is an empty cylinder the entrance area L3 will detect an alarm;...
  • Page 11: Meaning Of Front Leds

    Example of connection of UR Fog outputs to an alarm system with input zones "BALANCED" In this diagram, putting the resistance value required by the alarm control panel used in the terminal UR Fog, with not used outputs the central will see the correct resistance, while following the activation of an output, you will have a pull-down causing the alarm of the corresponding zone.
  • Page 12: Setting Shooting Time And Fog Flow Direction

    If you desire to obtain 1 meter visibility average after 60 seconds, as specified by the standard EN50131-8, and is used as reference by all manufacturers of Fog generators, the second value in m³ of fog has to be redoubled. Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013...
  • Page 13: Installation, Exchange And Cylinders Reset

    RISK OF BURNS IF TOUCHED by hands INSTALLATION, EXCHANGE AND CYLINDERS RESET The cylinders for fog cannons Fast 02 and Fast 03 are guaranteed to work for 3 years from production date. The expiry date is printed on the top of them.
  • Page 14: Maintenance

    MAINTENANCE UR Fog generators not require special care, however, it is recommended the support of qualified and authorized personnel for periodic annual monitoring, taking into account the following: - The charged cylinders have a limit of predetermined duration of 3 years.
  • Page 15 We recommend to throw away the batteries in the appropriate waste containers for recycling. Heavy metals contained in them are recoverable Empty cylinders are in aluminum for Fast 02 and steel for Fast 03 Metals are easily recyclable. Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013...
  • Page 16: Defects And Possible Solutions

    The jumper P3 stands in the See the setting mode of the shooting time at paragraph sound and the LEDs do “RESET” position not flash Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013 Page 16 di 19...
  • Page 17: Warranty

    Warranty The warranty of UR Fog is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine.
  • Page 18 MAINTENANCE DATE BATTERY EXCHANGE CYLINDER EXCHANGE SIGNATURE Installation and use manual models FAST 02 e FAST 03 rev 1.0.0 October 2013 Page 18 di 19...
  • Page 19 DICHIARAZIONE DI CONFORMITA' DECLARATION OF CONFORMITY COSTRUTTORE: UR Fog srl, sede legale: Via Giacinto Collegno 11 - 10143 - Torino - Italy Sede operativa: Via Poliziano n. 34 int.5 - 10153 -Torino - Italy MANUFACTURER: UR Fog srl, Legal office: Via Giacinto Collegno 11 - 10143 - Torino - Italy Operation and delivery to: Via Poliziano 34 int.

This manual is also suitable for:

Fast 03Fast a 03 1c tsFast a 03 2c tsFast a 02 2c ts

Table of Contents