Advertisement

Quick Links

INSTALLATION AND USER MANUAL
COMPACT
390
ENGLISH MANUAL
Installation and use manual model COMPACT rev. 01 Dec 2023 page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for UR FOG COMPACT 390

  • Page 1 INSTALLATION AND USER MANUAL COMPACT ENGLISH MANUAL Installation and use manual model COMPACT rev. 01 Dec 2023 page 1 of 20...
  • Page 2: Table Of Contents

    WARNING! All UR FOG fogging systems should only be used with UR FOG-branded fluids. It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl. SUMMARY Package contents page 2 Product presentation page 3...
  • Page 3: Product Presentation

    Do never stay for a long time in a room filled with fog. Do not use charged bags that are not the ones suggested by UR FOG and never try to recharge them, they are made for a single use.
  • Page 4: Installation Tips To Install Fogging Systems

    16. Do not move the machine when it is still hot. 17. The main body of COMPACT 390, which has the heating system enclosed inside a metal frame, should not be opened unless by specific and authorized service centers. Do not open and touch for any reason the insulation before 24 hours the unit has been shut off.
  • Page 5: Technical Specifications And Battery Endurance/Backup

    It is always recommended to secure the fog generator to a wall even when it is placed on a flat surface. The optional mounting kit for COMPACT 390, mainly recommended for ceiling installation, include both battery and fluid bag holders. An optional orientable (pan & tilt) module is available for wall mounting, it can also simplify standard installation by allowing to use back holes for the passage of cables.
  • Page 6: Electrical Power Supply

    ELECTRICAL POWER SUPPLY The 230V input provides primary power to the heat exchanger and, by the use of a switching power supply, to the electronic board and the pump. The heat exchanger’s working time without mains power ensures proper functioning for a certain period of time, usually around one hour, even in complete absence of mains power.
  • Page 7: Power Supply Connection

    POWER SUPPLY CONNECTION 12V Power supply connection 230V Power supply connection 230V Mains power Ground connection Battery slot (battery not included) - The battery installation is essential for the safe use of the device, it is monitored and recharged by the board’s circuit. - The housing for the 1.2A 12V lead-acid battery is lodged on right side of the exchanger.
  • Page 8 OUTPUT Power DC12 V 1-2 Output DC12v (max 200mA) for electrical connection of local devices connected to the board. It can be used to power a local PIR or a remote receiver. It is recommended not to overload the output. OUTPUTS 3 ARD/SHP - Reports the ARMING status (W2 open), or is active when TRIG is in progress (W2 close).
  • Page 9: Connection Examples

    CONNECTION EXAMPLES The diagrams and examples below are intended only for a “better understanding” of the operation of the inputs / outputs. None of the diagrams below represents the “single scheme to perform” as, in respect of the reference standard EN50131-8:2019, there are precise indications and only using all inputs and outputs on the PCB it is possible to abide by the standard.
  • Page 10 B - COMPACT inputs connected with a clean contact (relays) alarm panel outputs RELAY ARM ARM OUT RELAY TRIG TRIG OUT The ON/OFF output of this alarm panel is an open relay when panel is OFF that continuosly keep close for all the time the alarm panel is monitoring.
  • Page 11: Shooting Time Setting

    SHOOTING TIME SETTING AND FOG FLOW DIRECTION RESET SET TIME To set the shooting time, after opening the front panel, you must CLOSE the jumper W1 in SET position then, holding down the button S1, the green led on the front will flash and each flash is equivalent to one second fog emission. If you press the button again, the shooting time is not added to the one previously set, but will restart from zero.
  • Page 12 On the UR FOG Compact 390 mainboard are present two serial ports connectors (J11 and J6) that are reserved for connection to expansion modules and communication devices specially designed by the manufacturer. To allow advanced diagnostics, it is possible to connect a personal computer with Microsoft Windows or Linux operating system using a microUSB cable to the J1 port.
  • Page 13: Fluid Bag Installation, Exchange And Reset

    INSTALLATION, EXCHANGE AND BAG RESET Insert the bag in place as show in picture. Insert a new bag and push metal connector till a “click” is heard. Metal plug...
  • Page 14: Front Leds Meaning

    OFF: Device fault. The EMPTY signal also means that fluid is going LOW. It means that the unit has shot at least 100 seconds since last reset (COMPACT 390). The central RED low power light means unit is correctly powered on.
  • Page 15: Maintenance

    MAINTENANCE UR FOG fogging systems don’t need special maintance, nevertheless is suggested a periodical check to the following parts by skilled operators: 1) Verify battery and power supply status. 2) Verify screws are firmly closed. 3) Verify the output nozzle is not damaged and without anyting inside.
  • Page 16: Faults And Possible Solutions

    DEFECTS POSSIBLE SOLUTION DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION Small fog flow coming out All products are 100% This condition is normal and can happen on first from nozzle and a small ammount installation, it will completely disappear in a while of liquid could be still in when the unit will become completely hot.
  • Page 17 DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION Bag changed, reset needed Follow instructions Paragraph 13 Red front led BLINKING Empty bag - replace it following instructions on Paragraph 13 Green front led is BLINKING Unit still warming, wait max 60 min. with the unit connected to the mains power Unit ARMED Wires error...
  • Page 18: Warranty And Conditions Of Use

    WARRANTY The warranty of COMPACT 390 is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin.
  • Page 19: Maintenance And Operations

    MAINTENANCE DATE BATTERY EXCHANGE BAG EXCHANGE SIGNATURE It is mandatory to fill out this table in accordance with the security rules...
  • Page 20 N.B. Ask for the PDF module writing to: support@urfog.com TO USE UR FOG FOGGING SYSTEMS WITH PURIFOG FLUIDS FOLLOW THE DATASHEETS INSTRUCTIONS AVAILABLE FOR DOWNLOAD ON WWW.PURIFOG.COM UR FOG S.r.l. Via Toscana 38 - 10099 San Mauro Torinese - Italy...

Table of Contents