Blue LED flashes
The Buzzer sounds
continuously
BLUE and RED LEDs flash
alternatively
Does not arm,
BLUE LED does not power
on
When pressing the
cylinder reset button, the
buzzer doesn't sound and
all front LEDs flash but
red LED does not reset
The cylinder does not
enter
The cylinder does not exit
When setting shooting
time, the buzzer does not
sound and LEDs do not
flash
Installation and use manual FAST 01 NEW 220V
Overvoltage (110/220V)
Over temperature of the
electronic board
Disturbances / interferences or
potential differences between
equipments
Error in the heating system
Wiring error
P3 Jumper left in "SET" position
The plate is raised
The cylinder is stuck in the
valvebody
P3 Jumper left in "RESET"
position
Try to make a system reset like in Paragraph 16
In case of unsuccessful reset, possible fault of the
electronic board, contact technical support.
Verify that thare is sufficient ventilation Paragraph 5
For reset see Paragraph 16
Strong interferences (lightning) can cause a reading error
of the thermocouple, recover Paragraph 16
An unsuccessful reset may be due to potential
differences or to a fault.
In large size plants with more than one fog generator
connected to the same alarm centre, they may create
potential differences between equipments and it can be
necessary to uncouple them.
Possible faults: thermocouple, resistance or fuse
Do not try to repair
Contact tecnical support
Verify, once the alarm is on, that there is a tension of 11
V at least between - GND(5) + ARM(3)
CAUTION!!!
In this case shooting time has been reset
Cylinders reset – Paragraph 13
Shooting time setting - Paragraph 12
Follow instructions in paragraph 14
Pressure down and the pull
See shooting time settings in paragraph 13