UR FOG FAST 01 NEW Installation And Use Manual page 17

Table of Contents

Advertisement

17
FAULT
At power on, you hear a
relay clicking cyclically
At power on, you do not
hear a relay clicking
When the machine gets
armed, you hear a buzz
similar to a spinning
motor
When the machine gets
armed, if never shot, the
nozzle will blow a little
fog
The buzzer emits 1
bip/minute
The buzzer emits 2
bips/minutes
The buzzer emits 3
bips/minute
The buzzer emits 10
consecutive beeps each
minute
The machine is armed
(BLUE LED ON)
But does not shoot
Installation and use manual FAST 01 NEW 220V
FAULTS AND POSSIBLE SOLUTIONS
POSSIBLE CAUSE
It is not a fault
When the electronic board is
powered on, the microprocessor
makes a diagnostic test
Fixed green led
Green led powered off
The compressor verifies there is
not any obstruction or sabotage
in the fog emission circuit
All our machines are tested
during trial phase, thus a little
fog fluid always remain inside
the pipes
The +12 V input voltage is too
low or too high
Low battery but can still shoot
Low battery, can not shoot
No batteries inside
False contact battery case
Connector not inserted correctly Remove and reinsert the connector
In any case it is useful to use a tester to verify the presence of voltage on the battery case
The front red LED is on
The front green LED flashes
After arming, the machine does
not accept shooting command
Wiring error
POSSIBLE SOLUTION
When the machine is still cold or just shot, until it
reaches the working temperature, a relay is activated
together with the triac, in order to lower power
consumption
During the test, although green leds are flashing, the
heater is not working.
Wait few minutes
The heater reached the working temperature, so the
relay is not activated, if not occasionally
No 110/220V power supply, verify there is a tension on
the power connectors and wait few minutes
The compressor monitors the nozzle for about 15
minutes
After this time, it deactivates automatically.
Even if the machine gets unarmed, the compressor
keeps on working up to 15 minutes.
If the machine is unarmed and then rearmed, time count
starts from zero.
This ejection occurs when the machine is put into
operation for the first time and progressively decreases
until it completely disappears.
It can also occur after disassembling, reinstalling or
transport, during the first times the machine is activated.
Check the external power supply or the alarm unit
Replace batteries – See paragraph 15
Replace batteries – See paragraph 15
Insert batteries
Move the batteries,turn them
Reset of cylinders has not been made
Reset as described in paragraph 14
Empty cylinders – Change the cylinders as descrive in
paragraph 14
The heat exchanger has not yet reached minimum
temperature for shooting, waiting for flashing light to
stop (average heating time is 60')
For security reasons and to avoid false fog emissions
at power on, when the machine is armed, it
becomes effectively operating only after 20". After
this time, the emission is instantaneous.
Verify, once the alarm is on, that there is a tension of 12
V at least between - GND(5) + SHOOTS(4)
Page 17 of 21