Advertisement

Quick Links

INSTALLATION AND USE MANUAL
FAST
PRO PLUS
FAST 01 2C PRO PLUS
ENGLISH MANUAL
Installation and use manual model FAST 01 2C PRO PLUS 120 V/230 V rev. 15/02/2022 page 1 of 23

Advertisement

Table of Contents
loading

Summary of Contents for UR FOG FAST PRO PLUS

  • Page 1 INSTALLATION AND USE MANUAL FAST PRO PLUS FAST 01 2C PRO PLUS ENGLISH MANUAL Installation and use manual model FAST 01 2C PRO PLUS 120 V/230 V rev. 15/02/2022 page 1 of 23...
  • Page 2: Table Of Contents

    WARNING! All UR FOG fogging systems should only be used with UR FOG-branded fluids. It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl. SUMMARY Package contents page 2 Introduction of the product...
  • Page 3: Introduction Of The Product

    CONDITIONS OF USE AND WARNINGS The fog generated by UR Fog does not create particular problems or injuries for a human being for a short stay in a fogged room if the system is used according to the manufacturer’s recommendations.
  • Page 4: Installations Tips For Fogging Systems

    A shot that goes far beyond the recommended seconds can create a residue problems in the room 13. UR Fog continues to be effective for up to 2 hours without 230 V or 120 V main power thanks to the insulation system which maintains the temperature in the heating system.
  • Page 5: Technical Specifications

    TECHNICAL SPECIFICATIONS FAST 01 2C PRO PLUS * Industrial standard as from other manufacturers Weight without tanks 22 Kg Max fog emission in a single shot 1200 m Total fog emission capacity 1400 m Fog tanks capacity 2 x 600 ml Working time without mains power about 2,5 hours Max power on heating system...
  • Page 6: How To Activate The System

    HOW TO ACTIVATE THE SYSTEM It is always recommended to fix the fog generator to a wall even when it is placed on a flat surface. The optional bracket, is always recommended to simplify the installation, allowing to use back holes for the passage of cables.
  • Page 7: Mains Power Supply

    MAINS POWER SUPPLY The heating element is rated at 600 W, at the very beginning power consumption is about 500 W and in some minutes it goes down reaching average consumption of about 110 W. Do not use inverter or UPS if you are not sure that they generate a true sine wave, not a rebuilt one. Ask please to the UPS manifacturer the correspondance of such features before proceeding with the connection.
  • Page 8: Description Of Input And Output Connections

    While connecting the machine to the mains power, it is raccomended to never disconnect existing ground cable. The fact of disconnecting or modifing existing cables voids the warranty and can cause troubles or accidents related to the temperature control. DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS Shooting seconds setting Door tamper Cylinders reset...
  • Page 9 INPUTS + 12V Power input The power supply is connected to those inputs. INPUT SIGNALS A By connecting this input to positive, FAST 01 2C PRO PLUS is armed, blue frontal LED is switched on and when the machine reaches proper temperature it means that it is ready for shooting. S Putting this input to positive, if FAST 01 2C PRO PLUS is hot and armed, starts fog emission for the set time (see paragraph 11).
  • Page 10: Connection Examples

    PRO PLUS In the diagram above the control panel, as example, provides to UR Fog power supply between 11 and 14V DC 250 mA max. The ON/OFF output of this alarm is an Open Collector NPN opened when the system is off and it is stably closed to negative as long as the system turned on.
  • Page 11 GND OUT VALIDATION IN CENTRAL ALARM FAST PRO PLUS ON/OFF output of this alarm central is an open relay when the system is off and it is stably closed to positive as long as the system is turn on. Example of connection of FAST 01 2C PRO PLUS inputs with outputs of an alarm with open collector outputs...
  • Page 12 Example of connection of FAST 01 2C PRO PLUS outputs with balanced inputs of an antitheft In this diagram, by putting a resistance with a value +12V INPUT required by the alarm control panel used, in UR Fog GND INPUT ARM INPUT...
  • Page 13 Example of connection of FAST 01 2C PRO PLUS outputs with antirobbery connection ANTI-ROBBERY SHOOT ANTI-ROBBERY VALIDATION ANTI-ROBBERY COMMAND COMMAND Using the special connector and enabling the option antirobbery closing the Jumper W2, you will obtain the immediate emission of the fog for the seconds that you set (paragraph13) even if the fogging system is not armed.
  • Page 14: Front Leds Meaning

    MEANING OF FRONT LEDS BLUE LED When on The machine is armed and is hot, it’s ready to shoot. FAULT When flashing Something is wrong (See paragraph 17 DEFECTS AND POSSIBLE SOLUTIONS) RED LED EMPTY When on At least one cylinder is empty (See paragraph 14 INSTALLATION, EXCHANGE AND RESERVE CYLINDERS RESET) When flashing Something is wrong (See paragraph 17 DEFECTS AND POSSIBLE SOLUTIONS)
  • Page 15 SHOOTING TABLE FAST 02 1C PRO PLUS m³ Seconds m³ Seconds m³ Seconds to protect of emission to protect of emission to protect of emission 16-19 (57*) 401-482 (1446*) 786-944 (2832*) 32-39 (117*) 417-501 (1503*) 803-963 (2889*) 48-58 (174*) 433-520 (1560*) 819-982 (2946*) 64-77 (231*) 449-539 (1617*)
  • Page 16: Nozzle Tamper

    NOZZLE TAMPER The check of the nozzle obstruction is done with a little air flow, while a sensor check the pressure of the internal circuit. In case the sensor detect an increase of the internal pressure, means that there is an obstruction inside the nozzle. As consequence of the detection, the tamper output will be activated, the buzzer will emit a sound with a fast frequency with the flash of the red LEDs.
  • Page 17: Maintenance

    MAINTENANCE UR Fog generators do not require special care, however, it is recommended the support of qualified and authorized personnel for periodic annual monitoring, taking into account the following: 1) Verify the good working condition of the power supply and battery...
  • Page 18 IT’S ADVISABLE TO USE GLOWES 1 – Obstruct the nozzle with soft and insulating material (for example an eraser). 2 – Keep the nozzle obstructed, press the button P3 previously moved in RESET position (see paragraph 14) and keep it pressed until you hear that the pump is activated.
  • Page 19: Reset From Fault Conditions

    RESET FROM FAULT CONDITION This process is useful to discriminate false interpretations of faults caused by electrical shocks or serious problems on power supply from thermal loop problems. 1) Serious fault signal occurs with a first phase when the buzzer emits a continuous sound for 20 minutes and blue led flashes, the output FAULT immediately switch (if the generator is disconnected and connected again you can go directly at point 3) 2) After 20 minutes, the buzzer stops, while blue led goes on flashing, the FAULT output remains closed.
  • Page 20: Defects And Possible Solutions

    DEFECTS POSSIBLE SOLUTION DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION When you connect the machine It’s not a fault When the machine is cold or has just emitted fog, until the you hear a relay clicking cyclically exchanger has reached the working temperature, a relay is activated with the triac to decrease the consumption.
  • Page 21 Wiring error Verify that the alarm, once activated, has tension on connectors of at least 12 V between GND(5) + SHOOTS(4) Overvoltage power line Try to reset. See paragraph 16 (120/230 V) In case of unsuccessful restore the PCB can be damaged, contact the assistance service.
  • Page 22: Warranty

    WARRANTY The warranty of UR Fog is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine.
  • Page 23: Maintenance

    MAINTENANCE DATE BATTERY EXCHANGE CYLINDER EXCHANGE SIGNATURE It is mandatory to fill out this table in accordance with the law...
  • Page 24 N.B. Ask for the PDF module writing to: support@urfog.com UR Fog S.r.l. Via Toscana 38 - 10099 San Mauro T.se (Torino) - Italy...