Malfunctions-Troubleshooting; Additional Equipment; Recycling - Jøtul I 570 Manual

Hide thumbs Also See for I 570:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 66
ENGLISH
8.0 Troubleshooting
Poor draught
Check the length of the chimney so that it meets the
requirements of national laws and regulations. (See also
sections "2.0 Technical data" and "5.0 Daily use" (Chimney
and fl ue).
Check that min. The cross section of the chimney is in
accordance with what is described in «2.0 Technical data» in
the installation manual. Make sure that there is nothing to
prevent the fl ue gases from escaping: Branches, trees etc.
If there is a suspicion of excessive / poor draft in the chimney,
professional help must be sought for measurement and repair.
The fi re dies out after a while
Check that the fuel is dry enough.
Check if there is negative pressure in the house; close
mechanical fans and open a window near the fi replace.
Check that the air valve is open.
Make sure that the smoke outlet is not clogged with soot.
If an abnormal amount of soot is formed
on glass
There will always be some soot on the glass, but the amount
will depend on:
The moisture in the fuel.
The local draft conditions.
Adjustment of the air valve.
Most of the soot coating will normally be burned off when
the air valve is regulated up to the maximum, and it is fi red
fresh in the fi replace.
76

9.0 Additional equipment

9.1 Decor frame
Kat. nr. 50013035
9.2 Ash solution
Kat. nr. 50012921

10.0 Recycling

10.1 Recycling of packaging
The fi replace is delivered with the following
packaging:
Wooden pallet that can be cut up and burned in the
fi replace.
Packaging in cardboard to be delivered for recycling.
Plastic bags to be delivered for recycling.
Plastic vault supports are delivered for recycling.
10.2 Recycling the fi replace
The fi replace consists of:
Metal to be delivered for recycling.
Glass to be handled as special waste. The glass in the
fi replace must not be placed in normal source sorting.
Burning plates in verchulite that can be thrown in ordinary
residual waste..

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs 166

Table of Contents