Main Display Features

Main Display - If VTBI has not been set (flow sensor must be used)
Infusion Status /
Drug Name / Profile Name /
Primary or Secondary (Only if
secondary is enabled in the
data set)
Infusion Rate
Volume Infused
Softkey Identifiers
Softkeys
Main Display - If VTBI is set
Infusion Status / Drug Name
/ Profile Name /Primary or
Secondary (Only if secondary
is enabled in the data set)
Infusion Rate
Dose Rate
Volume to be Infused
Volume Infused
Time remaining
Softkey Identifiers
Softkeys
Screen Icons
Symbol
Description
Time remaining display icon - Indicates time remaining before VTBI will be completed. If the time is greater than
24 hours then 24+ will be displayed.
N
Battery icon - Indicates battery charge level to highlight when the battery will require recharging.
Pressure Information icon - Shows the pressure from level 0 being the first bar to level 8. Alarm limits: level 0 - 8.
?
Indicates that the value entered is outside of the Guardrails soft limits. The warning can be overridden (Indicates
Guardrails safety protocol is in use).
!
Indicates that the value entered is outside of the hard limits. The warning can NOT be overridden. This symbol is
also used to prompt the user to set the rate.
Indicates that the pump is running at a rate below (pointing down) a Guardrails Soft Limit.
Indicates that the pump is running at a rate above (pointing up) a Guardrails Soft Limit.
ON HOLD
RATE
25.0
VOLUME
VOLUME
Clear Volume Infused
Set VTBI Option
ADRENALINE
RATE
25
.0
16.
7
VTBI
VOLUME
1h
48m
VOLUME
Clear Volume Infused
Set VTBI Option
1000DF00546 Issue 5
Alaris™ GP (Guardrails™) Volumetric Pump
ml/h
50
.0
ml
VTBI
ml/h
µg/kg/24h
45
.0
ml
50
.0
ml
00s
VTBI
7/50
Main Display Features
a)
ON HOLD
SET RATE WITH
RATE
ON HOLD
If the rate has not been set and is
ON HOLD
showing at 0.0ml/h, then message a)
RATE TOO LOW
SET RATE WITH
will be displayed.
RATE
RATE
b)
ON HOLD
ON HOLD
ON HOLD
RATE TOO HIGH
SET RATE WITH
RATE TOO LOW
RATE
RATE
RATE
ON HOLD
ON HOLD
If programmed rate is between 0.0ml/h
and 0.1ml/h exclusive in drug protocol,
RATE TOO LOW
RATE TOO HIGH
message b) will be shown.
RATE
RATE
c)
ON HOLD
RATE TOO HIGH
RATE
If programmed rate is greater than the
INFUSION RATE MAX in drug protocol,
message c) will be shown.