Festo FB13 Electronic Manual page 182

Valve terminal, field bus connection, field bus protocol: profibus dp 12 mbaud, type 03/05
Hide thumbs Also See for FB13:
Table of Contents

Advertisement

VIFB13 - 03/05
Pin
assignment
(adapter
plate)
Circuitry
examples
and internal
structure
type 05
Fig. A/4b: Circuitry example: operating voltage connection type 05
9701 NH
Appendix A
Operating voltage connection type 05
1: 24 V supply
to electronic
components
and inputs
4: PE
Electrical
outputs (must be
fused externally)
Electrical
inputs/sensors
(fused internally)
24 V electronic
components
(fused internally)
Power unit
(e.g. central
power supply)
AC
230 V
DC
2 A
4
3.15 A
10 A
EMERG. STOP
2: 24 V supply to
outputs/valves
3: 0 V
Adapter cable
4 A
Valves max. 50%
simultaneity
(internally fused)
1
2
3
Operating voltage
connection for valve
terminal
24 V ± 10 %
24 V ± 10 %
0 V
PE
A-13