  • Page 1 MDF4220HD Commissioning English 004709 / 2.0.0 / 2017-01-17...
  • Page 2 Redmond, Washington, USA. Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the com- plete identification of third-party trademarks and indication of the respective holder of rights.
  • Page 3: Table Of Contents

    Commissioning MDF4220HD Table of Contents 1 Validity 2 Documents Data Sheet Commissioning Configuration 3 Typographical Conventions 4 Safety Instructions 5 General Notes Scope of Delivery Transportation and Packaging Warranty Approvals/Certifications Appropriate Use 6 Requirements General Operation 7 Maintenance 8 Product Variants...
  • Page 4: Validity

    MDF4220HD Commissioning 1 Validity This document applies to the following device: • MDF4220HD Figures in this document may differ from the actual product. 2 Documents Data Sheet The document “Data sheet” contains detailed technical specifications and features of the device.
  • Page 5: Typographical Conventions

    Commissioning MDF4220HD 3 Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger:  DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.  WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 6 MDF4220HD Commissioning For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows ( ➡ ): ➡ Carry out instructions one after the other in the sequence described.
  • Page 7: Safety Instructions

    • System Components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 8 MDF4220HD Commissioning • Documentation Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and warnings. The product documentation contains several documents which are included in the delivery in printed form and/or on a digital medium.
  • Page 9 Commissioning MDF4220HD • Operating Conditions Unfavourable operating conditions may shorten the life of the device and may cause malfunctions, damages and data loss and may result in the loss of war- ranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
  • Page 10: General Notes

    Certain functions and features may require the purchase of an additional license. Transportation and Packaging Store the original packaging for later transportation. Dallmeier is not responsible for any damage resulting from unprofessional/im- proper transportation. The device should only be shipped in the original packaging.
  • Page 11: Warranty

    • CE, FCC, ACA, UVV “Kassen” (DGUV Test), UL, DIN 50130-4 compliant Visit www.dallmeier.com for possible updates. Note (USA) This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to Part 15 of the FCC Rules.
  • Page 12: Appropriate Use

    MDF4220HD Commissioning Appropriate Use The MDF4220HD is a hybrid HD mini box camera. In addition to HD video over IP (Ethernet), the hybrid camera provides for a simul- taneous analog SD (PAL/NTSC) video output via BNC (CVBS). The camera is designed for indoor installations and can be powered via PoE (Power over Ethernet, Class 0, IEEE 802.3af) or supplied with 12 V DC...
  • Page 13: Requirements

    Commissioning MDF4220HD 6 Requirements General Unfavourable local conditions may shorten the lifetime of the product and may cause malfunctions or damages. Do not install/operate the device in places • with a large amount of dust and dirt, • with steam or oil vapours (e.g. kitchen), •...
  • Page 14 MDF4220HD Commissioning • Always disconnect the separate 12 V DC power supply unit from the mains socket (pull out the power plug) before connecting or disconnecting the device. • In order to comply with UL’s requirements, always use a UL-certified, Limited Power Source (LPS) Class 2 power supply unit when operating the device with a separate 12 V DC power supply unit.
  • Page 15: Maintenance

    Commissioning MDF4220HD 7 Maintenance The device may only be opened by qualified personnel for commissioning, inspection, maintenance and repair. Cleaning If it is necessary to clean the device, observe the following notes: NOTICE Damage to the surface of the device ➡...
  • Page 16: Product Variants

    MDF4220HD Commissioning 8 Product Variants Monofocal lens F2.0 / 2.4 mm www.dallmeier.com...
  • Page 17 Commissioning MDF4220HD ⓐ Locking screw (focus) ⓑ Locking screw (focal length) ⓑ ⓐ Varifocal lens F2.0 / 2.8 – 6 mm www.dallmeier.com...
  • Page 18: Mounting Variants

    MDF4220HD Commissioning 9 Mounting Variants The installation of the device may only be carried out by qualified personnel. ⓐ ❶ Knurled screw M3×8 mm (2×) ⓐ www.dallmeier.com...
  • Page 19 Commissioning MDF4220HD More mounting variants can be found in the product data sheet on: www.dallmeier.com www.dallmeier.com...
  • Page 20 MDF4220HD Commissioning ❷ ⓐ Knurled screw M3×8 mm (2×) ⓐ www.dallmeier.com...
  • Page 21 Commissioning MDF4220HD More mounting variants can be found in the product data sheet on: www.dallmeier.com www.dallmeier.com...
  • Page 22 MDF4220HD Commissioning ❸ ⓐ ⓐ Thread for 1/4" tripod screw www.dallmeier.com...
  • Page 23 Commissioning MDF4220HD ⓐ Ceiling bracket with 1/4" tripod screw ⓐ www.dallmeier.com...
  • Page 24 MDF4220HD Commissioning ❹ ⓐ Thread for 1/4" tripod screw ⓐ www.dallmeier.com...
  • Page 25 Commissioning MDF4220HD ⓐ Wall mount bracket with 1/4" tripod screw ⓐ www.dallmeier.com...
  • Page 26 MDF4220HD Commissioning ❺ ⓐ Knurled screw M3×8 mm (2×) ⓑ Thread for 1/4" tripod screw ⓑ ⓐ www.dallmeier.com...
  • Page 27 Commissioning MDF4220HD ⓐ Wall mount bracket with 1/4" tripod screw ⓐ www.dallmeier.com...
  • Page 28 MDF4220HD Commissioning ❻ ⓐ Knurled screw M3×8 mm (2×) ⓐ www.dallmeier.com...
  • Page 29 Commissioning MDF4220HD ⓐ www.dallmeier.com...
  • Page 30: Cabling

    MDF4220HD Commissioning 10 Cabling The commissioning of the device may only be carried out by qualified personnel.  WARNING Electric shock hazard Danger of death or serious injury ➡ Always disconnect the PoE switch or the separate power supply unit from the mains socket (pull out the power plug) before connecting or disconnecting the device.
  • Page 31 Commissioning MDF4220HD LAN (RJ45) / PoE (Class 0, IEEE 802.3af) Power IN (12 V DC) Analogue Video OUT (BNC RG-59) When using a separate 12 V DC power supply unit, interference caused by a ground loop may occur in the analog video signal.
  • Page 32: Connection And Login

    MDF4220HD Commissioning 11 Connection and Login The configuration of the device is carried out with a PC and web browser over the local area network (LAN). Alternatively, the PC can be directly connected to the device via an Ethernet crossover cable (if the device is powered via Power over Ethernet, a PoE injector is additionally required).
  • Page 33 DirectX 9.0 or 10.0 compatible 64 MB of graphics memory (128 MB or higher recommended) Ethernet 100 Mbps Web browser Microsoft Internet Explorer (latest version) Software Adobe Flash Player (latest version) JavaScript enabled Microsoft ActiveX enabled Dallmeier Live Video ActiveX (latest version) www.dallmeier.com...
  • Page 34 • a more powerful PC is required if several devices are simultaneously configured with live video display. • a DirectX compatible graphics card and the Dallmeier Live Video ActiveX are not required for the configuration without live video display. • the latest version of the Dallmeier Live Video ActiveX can be directly down- loaded from the device or from www.dallmeier.com.
  • Page 35: Connection

    Commissioning MDF4220HD Connection The factory default IP address of the device is 192.168.2.28. ➡ Ensure that the PC/web browser can establish a connection to the device via Ethernet. ➡ Start the web browser. ➡ Enter the IP address of the device into the address bar of the web browser.
  • Page 36: Login

    MDF4220HD Commissioning Login The graphical user interface of the configuration mode is displayed for authorized users only. The factory default admin password is “3”. NOTICE Risk of misuse by unauthorized users ➡ Change the factory default admin password as soon as possible.
  • Page 37: Technical Specifications

    Commissioning MDF4220HD 12 Technical Specifications Specifications Sensor 1/3" 1.3-megapixel CMOS image sensor Analog video output 1× BNC (CVBS, 1.0 V , 75 ohm) Ethernet 1× RJ45 female connector, 10BASE-T-/100BASE-TX-PoE Voltage supply 12 V DC ±10 % via PoE (Class 0) PoE standard IEEE 802.3af Power consumption 2.9 W typical (max.