Advertisement

Quick Links

DDF5(X)00HDV-DN
SM
Commissioning
English
005318 / 1.0.0 / 2015-01-29

Advertisement

Table of Contents
loading

Summary of Contents for dallmeier DDF5(X)00HDV-DN

  • Page 1 DDF5(X)00HDV-DN Commissioning English 005318 / 1.0.0 / 2015-01-29...
  • Page 2 Redmond, Washington, USA. Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the com- plete identification of third-party trademarks and indication of the respective holder of rights.
  • Page 3: Table Of Contents

    Commissioning DDF5(X)00HDV-DN-SM Contents 1 Validity 2 Documents This Document Other Applicable Documents 3 Typographical Conventions 4 Safety Instructions 5 General Notes Scope of Delivery Transportation and Packaging Warranty Approvals/Certifications Appropriate Use Operation 6 Requirements Ambient Conditions Power Supply 7 Maintenance...
  • Page 4: Validity

    Always follow the instructions, notes and warnings and observe the technical specifications in the product data sheet. Keep all documents in legible condition and in a suitable location for future refer- ence. Regularly check the website www.dallmeier.com for the latest updates on product documentation. www.dallmeier.com...
  • Page 5: This Document

    Commissioning DDF5(X)00HDV-DN-SM This Document Commissioning The document “Commissioning” (this document) contains detailed descriptions on installation, connection and commissioning of the device as well as safety instruc- tions and general notes. The target audience of this document is trained system integrators.
  • Page 6: Typographical Conventions

    DDF5(X)00HDV-DN-SM Commissioning 3 Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger:  DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.  WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 7 Commissioning DDF5(X)00HDV-DN-SM For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows ( ➡ ). ➡ Always carry out instructions one after the other in the sequence described.
  • Page 8: Safety Instructions

    • System Components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 9 Commissioning DDF5(X)00HDV-DN-SM • Documentation Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and warnings. The product documentation contains several documents which are included in the scope of delivery in a printed form and/or on a digital medium.
  • Page 10 DDF5(X)00HDV-DN-SM Commissioning • Operating Conditions Unfavorable operating conditions may shorten the life of the device and may cause malfunctions, damages and data loss and may result in the loss of war- ranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
  • Page 11: General Notes

    Transportation and Packaging Store the original packaging for later transportation. Dallmeier is not responsible for any damage resulting from unprofessional/im- proper transportation. The device should only be shipped in the original packaging. If the original packaging is no longer available, ensure that the used packaging suf- ficiently protects the device against damage, moisture, heat and cold.
  • Page 12: Warranty

    The terms and conditions valid at time the contract was signed shall apply. Approvals/Certifications The following approvals/certifications were valid for the device at the time of this document’s compilation: • CE, FCC, ACA, UL, DIN 50130-4 compliant Visit www.dallmeier.com for possible updates. www.dallmeier.com...
  • Page 13: Appropriate Use

    Commissioning DDF5(X)00HDV-DN-SM Appropriate Use The DDF5(X)00HDV-DN-SM (surface mount variant) is a HD network camera built into a vandal-resistant (IK10) dome enclosure. It is designed for indoor installations on ceilings and walls and can be powered via PoE (Power over Ethernet, Class 0, IEEE 802.3af) or supplied with a separate power supply unit.
  • Page 14: Operation

    DDF5(X)00HDV-DN-SM Commissioning Operation • When using a separate power supply unit, interference caused by a ground loop may occur in the analog video signal. In this case, use a video signal transformer (balun) for galvanic (ground) isolation between the signal source (camera) and the RG-59 cable.
  • Page 15: Requirements

    Commissioning DDF5(X)00HDV-DN-SM 6 Requirements Ambient Conditions Unfavorable local conditions may shorten the lifetime of the product and may cause malfunctions or damages. ➡ Do not install/operate the device in places • with a large amount of dust and dirt, • with steam or oil vapors (e.g. kitchen), •...
  • Page 16: Power Supply

    DDF5(X)00HDV-DN-SM Commissioning Power Supply The device can be powered via PoE (Power over Ethernet, Class 0, IEEE 802.3af) or supplied with a separate power supply unit.  WARNING Electric shock hazard Danger of death or serious injury ➡ Always disconnect the separate power supply unit from the mains socket (pull out the power plug) before connecting or disconnecting the device.
  • Page 17 Commissioning DDF5(X)00HDV-DN-SM NOTICE Damage to the device resulting from improper power supply ➡ Always ensure the correct polarity when using a separate power supply unit. ➡ Do not use PoE (Power over Ethernet) and a separate power supply unit simultaneously.
  • Page 18: Maintenance

    DDF5(X)00HDV-DN-SM Commissioning 7 Maintenance The device may only be opened by qualified personnel for commissioning, inspec- tion, maintenance and repair. Cleaning If it is necessary to clean the device, observe the following notes: NOTICE Damage to the surface of the device ➡...
  • Page 19: Installation

    Commissioning DDF5(X)00HDV-DN-SM 8 Installation The installation of the device may only be carried out by qualified personnel.  WARNING Falling device/objects or collapsing ceiling Danger of death or serious injury to the head ➡ Observe the manufacturer’s instructions about the maximum adequate carrying capacity of the supporting structure.
  • Page 20 DDF5(X)00HDV-DN-SM Commissioning ❶ ⓐ Torx screwdriver (T20) ⓐ www.dallmeier.com...
  • Page 21 Commissioning DDF5(X)00HDV-DN-SM ⓐ T20 torx screw (3×) ⓐ ➡ Loosen the torx screws of the housing. www.dallmeier.com...
  • Page 22 DDF5(X)00HDV-DN-SM Commissioning ❷ ➡ Remove the housing/bubble. www.dallmeier.com...
  • Page 23 Commissioning DDF5(X)00HDV-DN-SM ❸ ⓐ Threaded blanking plug ⓑ O-ring ⓐ ⓑ ➡ Remove the threaded blanking plug of the side cable entry (use a screw- driver). www.dallmeier.com...
  • Page 24 DDF5(X)00HDV-DN-SM Commissioning ⓐ Alternative cable feedthrough ⓐ Always use the threaded blanking plug and O-ring to securely seal the un- used cable entry (the O-ring is only required when sealing the side cable entry, see previous page). www.dallmeier.com...
  • Page 25 Commissioning DDF5(X)00HDV-DN-SM ❹ ⓐ ⓑ ⓐ Gasket (adhesive-backed) ⓑ Threaded blanking plug ➡ Adhere the delivered gasket to the bottom of the housing base. www.dallmeier.com...
  • Page 26 DDF5(X)00HDV-DN-SM Commissioning ❺ ⓐ ⓑ ⓐ Drill hole (3×) ⓑ Dowel/anchor (3×) ⓒ ⓒ O-ring (3×) ⓓ Mounting screw (3×) ⓓ www.dallmeier.com...
  • Page 27 Commissioning DDF5(X)00HDV-DN-SM ⓐ Screwdriver ⓐ ➡ Mark the drill holes on the ceiling/wall (use the delivered drilling template). ➡ At the marked locations, drill holes fitting the used screws/anchors. ➡ Push anchors suitable for the ceiling/wall material into the drill holes.
  • Page 28 DDF5(X)00HDV-DN-SM Commissioning ❻ ⓐ ⓑ ⓐ PG16 cable gland ⓑ O-ring ➡ Run the required cables through a PG16 cable gland. www.dallmeier.com...
  • Page 29 Commissioning DDF5(X)00HDV-DN-SM ➡ Screw the PG16 cable gland in the appropriate thread of the housing base (always use the O-ring for the side cable entry). www.dallmeier.com...
  • Page 30 DDF5(X)00HDV-DN-SM Commissioning ❼ ⓐ ⓗ ⓖ ⓕ ⓔ ⓓ ⓑ ⓒ ➡ Connect the required cables to the connectors of the camera module. www.dallmeier.com...
  • Page 31 Commissioning DDF5(X)00HDV-DN-SM ⓐ Analog video output (BNC, CVBS, 1.0 V  , 75 Ω) ⓑ Memory card slot (microSDXC ⓒ Reserved port (not used) ⓓ Audio Line OUT (3.5 mm phone jack) ⓔ Audio Line IN (3.5 mm phone jack) ⓕ LAN / PoE (RJ45 jack, PoE conformity IEEE 802.3af) ⓖ...
  • Page 32 DDF5(X)00HDV-DN-SM Commissioning ❽ ⓐ ⓐ microSDXC card (64 GB – 2 TB, UHS II) www.dallmeier.com...
  • Page 33 Commissioning DDF5(X)00HDV-DN-SM ❾ ⓐ Knurled locking screw “Rotation” (2×) Tilt ±90° Pan ±90° Rotation ±180° ⓐ www.dallmeier.com...
  • Page 34 DDF5(X)00HDV-DN-SM Commissioning ❿ ⓑ ⓐ www.dallmeier.com...
  • Page 35 Commissioning DDF5(X)00HDV-DN-SM ⓐ Motor-driven P-Iris varifocal lens ⓑ Ambient light sensor Remote Zoom & Focus Control The camera is equipped with a motor-driven varifocal lens. The focal length (zoom) and the focus are adjusted over the network in the “WebConfig” user interface of the camera (more information can be found in the documentation on camera configuration).
  • Page 36 DDF5(X)00HDV-DN-SM Commissioning ⓫ ⓐ Black inner dome cover ⓐ ➡ Attach the housing to the housing base while ensuring that the ambient light sensor is not covered by the black inner dome cover. www.dallmeier.com...
  • Page 37 Commissioning DDF5(X)00HDV-DN-SM ⓬ ➡ Tighten the 3 torx screws of the housing with a T20 torx screwdriver. www.dallmeier.com...
  • Page 38: Pin Assignment

    DDF5(X)00HDV-DN-SM Commissioning 9 Pin Assignment Power + Power − Power IN Weidmüller male connector SL 3.50/02/90G (mating connector Weidmüller BL 3.50/02/180 SN) In order to comply with UL’s requirements, always use a UL-certified, Limited Power Source (LPS) Class 2 power supply unit when operating the device with a separate power supply unit.
  • Page 39 Commissioning DDF5(X)00HDV-DN-SM Ring Sleeve Audio Line IN / Line OUT (2× 3.5 mm phone jack, for stereo plug) Audio Line IN (stereo) Line OUT (stereo) Left channel Left channel Ring Right channel Right channel Sleeve Ground Ground Audio Line IN (stereo) Input level: max.
  • Page 40: Connection And Login

    DDF5(X)00HDV-DN-SM Commissioning 10 Connection and Login The configuration of the device is carried out with a PC and web browser over the local area network (LAN). Alternatively, the PC can be connected directly to the device via an Ethernet crossover cable (if the device is powered via Power over Ethernet, a PoE injec- tor is additionally required).
  • Page 41 • a more powerful client PC is required if several devices are configured with live video display (and/or live audio output) simultaneously. • a DirectX compatible graphics card and the Dallmeier Live Video ActiveX are not required for the configuration without live video display or live audio output.
  • Page 42: Connection

    DDF5(X)00HDV-DN-SM Commissioning Connection The factory default IP address of the device is: 192.168.2.28 ➡ Ensure that your PC/web browser can establish a connection to the device via Ethernet (if necessary, contact your network administrator for more informa- tion and assistance).
  • Page 43: Login

    Commissioning DDF5(X)00HDV-DN-SM Login The graphical user interface (GUI) of the configuration mode is displayed for authenticated and authorized users only. The factory default login credentials of the administrator account are: User name: admin Password: 3 NOTICE Risk of misuse by unauthorized users ➡...
  • Page 44: Technical Specifications

    DDF5(X)00HDV-DN-SM Commissioning 11 Technical Specifications Connections/Interfaces Video preview output 1× BNC (CVBS, 1.0 V , 75 Ω) Audio Line IN (stereo) 1× 3.5 mm phone jack Input level: max. 2.83 V Input impedance: 29 kΩ Audio Line OUT (stereo) 1× 3.5 mm phone jack Output level at 10 kΩ load: max. 3.11 V Output impedance: 320 Ω...
  • Page 45 Approx. 1100 g (2.4 lb) Environmental Conditions Suitable installation sites Indoor and outdoor Operating temperature −20 °C to +50 °C (−4 °F to 122 °F) Relative humidity 0 % – 90 % RH, non-condensing For detailed technical specifications and possible updates, see the current product data sheet (available on www.dallmeier.com). www.dallmeier.com...
  • Page 46: Dimensions

    DDF5(X)00HDV-DN-SM Commissioning 12 Dimensions 152 mm (5.98") Ø 120 mm (4.72") 45 mm (1.77") Ø 4.5 mm (0.18") 113.80 mm (4.48") www.dallmeier.com...
  • Page 48 Dallmeier electronic GmbH & Co.KG Cranachweg 1 · 93051 Regensburg · Germany Phone +49 (0) 941 87 00-0 · Fax +49 (0) 941 87 00-180 www.dallmeier.com · info@dallmeier.com...

Table of Contents