Advertisement

Quick Links

DDF4520HDV-DN
SM
Commissioning
English
004729 / 1.0.1 / 2014-05-05

Advertisement

Table of Contents
loading

Summary of Contents for dallmeier DDF4520HDV-DN

  • Page 1 DDF4520HDV-DN Commissioning English 004729 / 1.0.1 / 2014-05-05...
  • Page 2 Redmond, Washington, USA Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the com- plete identification of third-party trademarks and indication of the respective holder of rights.
  • Page 3: Table Of Contents

    Commissioning DDF4520HDV-DN-SM Table of Contents 1 Validity 2 Documents Data Sheet Commissioning Configuration 3 Typographical Conventions 4 Safety Instructions 5 General Notes Scope of Delivery Transportation and Packaging Warranty Approvals/Certifications Appropriate Use 6 Requirements General Operation 7 Maintenance 8 Installation and Commissioning...
  • Page 4: Validity

    DDF4520HDV-DN-SM Commissioning 1 Validity This document applies to the following device: • DDF4520HDV-DN-SM (surface mount variant) Figures in this document may differ from the actual product. 2 Documents Data Sheet The document “Data sheet” contains detailed technical specifications and features of the device.
  • Page 5: Typographical Conventions

    Commissioning DDF4520HDV-DN-SM 3 Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger:  DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.  WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 6 DDF4520HDV-DN-SM Commissioning For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows ( ➡ ): ➡ Carry out instructions one after the other in the sequence described.
  • Page 7: Safety Instructions

    • System Components Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 8 DDF4520HDV-DN-SM Commissioning • Documentation Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and warnings. The product documentation contains several documents which are included in the delivery in printed form and/or on a digital medium.
  • Page 9 Commissioning DDF4520HDV-DN-SM • Operating Conditions Unfavourable operating conditions may shorten the life of the device and may cause malfunctions, damages and data loss and may result in the loss of war- ranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
  • Page 10: General Notes

    DDF4520HDV-DN-SM Commissioning 5 General Notes Scope of Delivery Included in the standard scope of delivery is: 1× Documentation “Configuration” (published on DVD-ROM) 1× Documentation “Commissioning” (published in print and on DVD-ROM) 1× Cable harness (Video OUT, Power IN) for indoor installations (pre-installed) 1×...
  • Page 11: Transportation And Packaging

    DDF4520HDV-DN-SM Transportation and Packaging Store the original packaging for later transportation. Dallmeier is not responsible for any damage resulting from unprofessional/im- proper transportation. The device should only be shipped in the original packaging. If the original packaging is no longer available, ensure that the used packaging suf- ficiently protects the device against damage, moisture, heat and cold.
  • Page 12: Appropriate Use

    DDF4520HDV-DN-SM Commissioning Appropriate Use The DDF4520HDV-DN-SM (surface mount variant) is a hybrid HD network camera built into a vandal-resistant (IK10) dome enclosure. In addition to HD video over IP (Ethernet), the hybrid camera provides for a simul- taneous analogue SD (PAL/NTSC) video output via BNC (CVBS).
  • Page 13 Commissioning DDF4520HDV-DN-SM NOTICE • For outdoor installations, carefully remove the pre- installed cable harness. Always use the delivered cable harness (Video OUT, Power IN, Ethernet) and the PG16 cable gland instead. • Protect the device from direct influence of weather conditions (rainfall, direct sunlight, etc.).
  • Page 14: Requirements

    DDF4520HDV-DN-SM Commissioning 6 Requirements General Unfavourable local conditions may shorten the lifetime of the product and may cause malfunctions or damages. Do not install/operate the device in places • with a large amount of dust and dirt, • with steam or oil vapours (e.g. kitchen), •...
  • Page 15 Commissioning DDF4520HDV-DN-SM • Always disconnect the separate 12 V DC power supply unit from the mains socket (pull out the power plug) before connecting or disconnecting the device. • In order to comply with UL’s requirements, always use a UL-certified, Limited Power Source (LPS) Class 2 power supply unit when operating the device with a separate 12 V DC power supply unit.
  • Page 16: Maintenance

    DDF4520HDV-DN-SM Commissioning 7 Maintenance The device may only be opened by qualified personnel for commissioning, inspec- tion, maintenance and repair. Cleaning If it is necessary to clean the device, observe the following notes: NOTICE Damage to the surface of the device ➡...
  • Page 17 Commissioning DDF4520HDV-DN-SM NOTICE Damage to the dome bubble ➡ Clean the plastic bubble with water and some dishwashing agent using a soft, non-linting cloth or sponge. • Do not rub the plastic bubble with a dry cloth. • Do not use common glass cleaners.
  • Page 18: Installation And Commissioning

    DDF4520HDV-DN-SM Commissioning 8 Installation and Commissioning The installation and commissioning of the device may only be carried out by quali- fied personnel.  WARNING Falling device/objects or collapsing ceiling Danger of death or serious injury to the head ➡ Observe the manufacturer’s instructions about the maximum adequate carrying capacity of the sup- porting structure.
  • Page 19 Commissioning DDF4520HDV-DN-SM NOTICE Damage to the device resulting from improper power supply The device can be powered via Power over Ethernet (PoE, Class 0, IEEE 802.3af) or supplied with a separate 12 V DC power supply unit. However, always beware not to use both power sources simultaneously.
  • Page 20 DDF4520HDV-DN-SM Commissioning ❶ ⓐ Torx screwdriver (T20) ⓐ www.dallmeier.com...
  • Page 21 Commissioning DDF4520HDV-DN-SM ⓐ T20 torx screw (3×) ⓐ ➡ Loosen the torx screws of the housing. www.dallmeier.com...
  • Page 22 DDF4520HDV-DN-SM Commissioning ❷ ➡ Remove the housing/bubble. www.dallmeier.com...
  • Page 23 Commissioning DDF4520HDV-DN-SM ❸ ⓐ Threaded blanking plug ⓑ O-ring ⓐ ⓑ ➡ Remove the threaded blanking plug of the side cable entry (use a screw- driver). www.dallmeier.com...
  • Page 24 DDF4520HDV-DN-SM Commissioning ⓐ Alternative cable feedthrough ⓐ Always use the threaded blanking plug and O-ring to securely seal the unused cable entry (the O-ring is only required when sealing the side cable entry, see previous page). www.dallmeier.com...
  • Page 25 Commissioning DDF4520HDV-DN-SM ❹ ⓐ ⓐ Connection board www.dallmeier.com...
  • Page 26 DDF4520HDV-DN-SM Commissioning ⓑ ⓒ ⓓ ⓐ ⓔ ⓐ Connection board ⓑ 4-pin male connector: Analogue Video OUT / 12 V DC Power IN ⓒ Shielded RJ45 Ethernet female connector / PoE (IEEE 802.3af) ⓓ 8-pin male connector: Ethernet / PoE (IEEE 802.3af) ⓔ...
  • Page 27 Commissioning DDF4520HDV-DN-SM NOTICE Damage to the device caused by improper wiring ➡ For outdoor installations, carefully remove the pre- installed cable harness (connector ⓑ). Always use the delivered outdoor cable harness (Video OUT, Power IN, Ethernet) and the PG16 cable gland instead.
  • Page 28: Indoor Installation

    DDF4520HDV-DN-SM Commissioning Indoor Installation Power In (12 V DC) ⓐ Analogue Video OUT (BnC rG-59) ⓐ Cable harness (pre-installed) Carefully remove the pre-installed cable harness if not used! You may remove the pre-installed cable harness if you want to use neither the 12 ...
  • Page 29: Outdoor Installation

    Commissioning DDF4520HDV-DN-SM Outdoor Installation rJ45 ethernet female connector / Poe (Ieee 802.3af) ⓑ ⓐ Power In (12 V DC) ⓐ Analogue Video OUT Cable harness (supplied) (BnC rG-59) ⓑ PG16 cable gland Damage or malfunction caused by improper outdoor installation! For outdoor installations, carefully remove the pre-installed cable harness.
  • Page 30 DDF4520HDV-DN-SM Commissioning ❺ ⓐ ⓑ ⓐ Gasket (adhesive-backed) ⓑ Threaded blanking plug ➡ Adhere the delivered gasket to the bottom of the housing base. www.dallmeier.com...
  • Page 31 Commissioning DDF4520HDV-DN-SM ❻ ⓐ ⓑ ⓐ Drill hole (3×) ⓑ Dowel/anchor (3×) ⓒ ⓒ O-ring (3×) ⓓ Mounting screw (3×) ⓓ www.dallmeier.com...
  • Page 32 DDF4520HDV-DN-SM Commissioning ⓐ Screwdriver ⓐ ➡ Mark the drill holes on the ceiling/wall (use the delivered drilling template). ➡ At the marked locations, drill holes fitting the used screws/anchors. ➡ Push anchors suitable for the ceiling/wall material into the drill holes.
  • Page 33 Commissioning DDF4520HDV-DN-SM ❼ ⓐ ⓑ ⓐ PG16 cable gland ⓑ O-ring ➡ Run the required cables through a PG16 cable gland. www.dallmeier.com...
  • Page 34 DDF4520HDV-DN-SM Commissioning ➡ Screw the PG16 cable gland in the appropriate thread of the housing base (always use the O-ring for the side cable entry). ➡ Connect the required cables to the connectors of the connection board. www.dallmeier.com...
  • Page 35 Commissioning DDF4520HDV-DN-SM ❽ ⓐ Knurled locking screw “Rotation” (2×) Tilt ±90° Pan ±90° Rotation ±180° ⓐ www.dallmeier.com...
  • Page 36 DDF4520HDV-DN-SM Commissioning ⓐ ❾ ⓐ Ambient light sensor Remote Zoom & Focus Control The camera is equipped with a motor-driven varifocal lens. The focal length (zoom) and the focus are adjusted over the network in the “WebConfig” user interface of the camera (more information can be found in the documentation on camera configuration).
  • Page 37 Commissioning DDF4520HDV-DN-SM ❿ ⓐ Black inner dome cover ⓐ ➡ Attach the housing to the housing base while ensuring that the ambient light sensor is not covered by the black inner dome cover. www.dallmeier.com...
  • Page 38 DDF4520HDV-DN-SM Commissioning ⓫ ➡ Tighten the 3 torx screws of the housing with a T20 torx screwdriver. www.dallmeier.com...
  • Page 39: Connection And Login

    Commissioning DDF4520HDV-DN-SM 9 Connection and Login The configuration of the device is carried out with a PC/web browser via the local area network (LAN). Alternatively, the PC can be directly connected to the device via an ethernet crossover cable. NOTICE...
  • Page 40 DirectX 9.0 or 10.0 compatible 64 MB of graphics memory (128 MB or higher recommended) Ethernet 100 Mbps Web browser Microsoft Internet Explorer (latest version) Software Adobe Flash Player (latest version) JavaScript enabled Microsoft ActiveX enabled Dallmeier Live Video ActiveX (latest version) www.dallmeier.com...
  • Page 41 • a more powerful PC is required if several devices are simultaneously configured with live video display. • a DirectX compatible graphics card and the Dallmeier Live Video ActiveX are not required for the configuration without live video display. • the Dallmeier Live Video ActiveX can be directly downloaded from the device.
  • Page 42: Connection

    DDF4520HDV-DN-SM Commissioning Connection The factory default IP address of the device is 192.168.2.28. ➡ Ensure that the PC/web browser can establish a connection to the device via Ethernet. ➡ Start the web browser. ➡ Enter the IP address of the device into the address bar of the web browser.
  • Page 43: Login

    Commissioning DDF4520HDV-DN-SM Login The graphical user interface of the configuration mode is displayed for authorized users only. The factory default admin password is “3”. NOTICE Risk of misuse by unauthorized users ➡ Change the factory default admin password as soon as possible.
  • Page 44: Technical Specifications

    DDF4520HDV-DN-SM Commissioning 10 Technical Specifications Specifications Sensor 1/3" 1.3-megapixel CMOS image sensor Analogue video output 1× BNC (CVBS, 1.0 V , 75 ohm) Ethernet 1× RJ45 female connector, 10BASE-T-/100BASE-TX-PoE Voltage supply 12 V DC ±10 % via PoE (Class 0) PoE standard IEEE 802.3af Power consumption Max.
  • Page 45: Www.dallmeier.com

    Commissioning DDF4520HDV-DN-SM Specifications Operating temperature −20 °C to +50 °C (−4 °F to 122 °F), indoor and outdoor Relative humidity 0 % – 90 % RH, non-condensing Approvals/certifications CE, FCC, ACA, UVV “Kassen” (DGUV Test), UL, DIN EN 50130-4 compliant For detailed technical specifications and product documentations go to: www.dallmeier.com...
  • Page 48 Dallmeier electronic GmbH & Co.KG Cranachweg 1 · 93051 Regensburg · Germany Phone +49 (0) 941 87 00-0 · Fax +49 (0) 941 87 00-180 www.dallmeier.com · info@dallmeier.com...

Table of Contents