The Error LED will be lit before a video signal has not yet been connected. This does not have a negative effect on the following
steps, however.
Secure the modle in the module rack using the four
screws on the front cover.
Connect the module to the PC you wish to use to confi-
cure it via the LAN.
A correct connection has been made if the orange LED on the LAN
interface is permanently lit.
The module and PC or laptop can also be connected direct using a cross cable.
Configure the IP address or DHCP as described in the
Configuration documentation.
Then install the next module as described above.
Duct Covers
For continuous operation it is essential that all ducts on the modu-
le rack are closed. This is necessary to maintain air circulation and
therefore to cool the modules.
Close all the ducts that are still open after you have installed the
modules, using the duct covers provided for this purpose.
Ensure that the EMC seal on the duct cover is on the right-hand
side.
If you do not have enough duct covers available, contact the Dallmeier support.
NOTICE
Open ducts on the module rack can result in serious damage to the modules in conti-
nuous operation (particularly a hard disk drive failure).
Commissioning
WARNING
Danger of death from electric shock in the event of a lightning strike!
Data transfer and video cables must not be connected or disconnected during a storm.
After the mounting in the ready for use module rack the module starts automatically. The power LED flashs.
Connect the camera to the module.
Connect the module to the network.
The module can be configured via the network after approx. 45 seconds.
Installation Module