Advertisement

Quick Links

DIS-4/M SRS
Commissioning
English
006065 / 1.0.5 / 2018-03-19

Advertisement

Table of Contents
loading

Summary of Contents for dallmeier DIS-4/M SRS

  • Page 1 DIS-4/M SRS Commissioning English 006065 / 1.0.5 / 2018-03-19...
  • Page 2 All trademarks identified by ® are registered trademarks of Dallmeier electronic. Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identification of third-party trademarks and indication of the respective holder of rights.
  • Page 3: Table Of Contents

    DIS-4/M SRS Table of Contents 1 Validity 2 Documents This Document Other Applicable Documents 3 Typographical Conventions 4 Safety Instructions 5 General Notions Transportation and Packaging Warranty Appropriate Use Approvals/Certifications Note (USA) 6 Requirements 7 Rack Installation Dimensions Mounting Duct Covers 8 Commissioning 9 Connections...
  • Page 4: Validity

    DIS-4/M SRS Validity This document applies to the SMAVIA Appliance DIS-4/M SRS. Figures in this document may differ from the actual product. Documents The product documentation contains several documents which are included in the scope of delivery in a printed form and/or on a digital medium.
  • Page 5: This Document

    DIS-4/M SRS This Document Commissioning The document “Commissioning” (this document) contains detailed de- scriptions on installation, connection and commissioning of the device as well as safety instructions and general notes. The target audience of this document is trained system integrators.
  • Page 6: Typographical Conventions

    DIS-4/M SRS Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger:  DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.  WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 7 DIS-4/M SRS For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows (➡). Expressions in bold and italic marks generally indicate a control element on the device (switches or labels) or on its user interface (buttons, menu items).
  • Page 8: Safety Instructions

    (UPS). A sudden voltage drop can damage the RAID system. Modifications Do not make any modifications to the hardware or software that have not been tested and approved by Dallmeier. Inappropriate modifications may cause malfunctions, damages and data loss and may result in the loss of warranty.
  • Page 9 “Specification” document. Keep all documents in legible condition and in a suitable location for future reference. Regularly check the website www.dallmeier.com for the latest updates on product documentation. Condensation Water If the device is brought from a cold to a warm environment, resulting con- densation water may cause malfunctions and damages.
  • Page 10 DIS-4/M SRS Shocks Shocks can cause malfunctions and damages. The unit may not be moved while in operation. Foreign Bodies If objects or liquids get into the device, immediately disconnect it from the power supply (pull out the power plug). Contact the sales partner responsible for your area.
  • Page 11: General Notions

    The terms and conditions valid at time the contract was signed shall apply. Appropriate Use The appliance DIS-4/M SRS has been designed as a compact 3 RU slide-in module for highly available storage systems of larger video installations in stadiums, shopping malls, casinos or convention centres. In conjunc-...
  • Page 12: Approvals/Certifications

    • RCM • UL • DIN 50130-4 compliant Visit www.dallmeier.com for possible updates. Note (USA) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence when the equipment is operated in a commercial environment.
  • Page 13: Requirements

    DIS-4/M SRS 6 Requirements The appliance has to be mounted in the according module carrier, which is to be operated in a 19'' standard rack with active ventilation. The re- quired rails are included in the scope of delivery. Rack Installation ➡...
  • Page 14 DIS-4/M SRS Power Supply of the rack ➡ Operate the rack with 115/240 V AC, 50/60 Hz. ➡ Use an uninterruptible power supply (UPS) to protect the device from voltage spikes and to keep it in operation in case of power failure. NOTICE Prevention of separation from the circuit The plug of the supply line serves as separator from the supply circuit.
  • Page 15: Rack Installation

    DIS-4/M SRS Rack Installation The installation and commissioning of the device may only be carried out by qualified personnel. The following tools are needed for the installation: • Cross recess screwdriver (5 mm) Dimensions 109 mm 129 mm 538 mm 41 mm...
  • Page 16: Mounting

    DIS-4/M SRS Mounting  CAUTION Risk of damages and injury through electric shock ➡ Ensure that all devices are disconnected from the mains supply. A free duct should be available for every module you have ordered. Start on the left-hand side of the module rack. The modules must later be installed in sequence from left to right.
  • Page 17 DIS-4/M SRS  WARNING Risk of electric shock The module rack can already be live. ➡ Do not reach into the open housing of the module rack. ➡ Do not insert any objects. ➡ To install modules always use the first empty duct from the left-hand side of the module rack.
  • Page 18 DIS-4/M SRS ➡ Insert the module into the guide rails (top and bottom). ➡ Carefully slide the module into the module rack. ➡ Ensure that you slide it straight. Do not use any force. The module is inserted correctly when it has been fully slid in and engaged.
  • Page 19: Duct Covers

    DIS-4/M SRS Duct Covers For continuous operation it is essential that all ducts on the module rack are closed. This is necessary to maintain air circulation and therefore to cool the modules. ➡ Close all the ducts that are still open after you have installed the mod- ules, using the duct covers provided for this purpose.
  • Page 20: Commissioning

    DIS-4/M SRS 8 Commissioning In order do continue the commissioning of the appliances, the module carrier has to be installed in the rack. Notice the according documenta- tion “Commissioning DIS Module Rack”. ➡ Connect the device to the voltage supply.
  • Page 21: Connections

    DIS-4/M SRS Connections Video OUT Interface 1× DisplayPort eDP 1.3 Ethernet Interface 1 RJ45, 10/100/1000 Mbps (optional) USB Interface 1× USB 3.0, type A Contact IN / Relay OUT Weidmüller socket, 16 pins, max. 12 V DC / 24 V AC / 0,5 A, 150 mOhm Status LED (Power) Blue / The device is in operation;...
  • Page 22: Login

    DIS-4/M SRS 10 Login In the initial state it is possible to login without a password. The rights of the Administrator group are valid. he definition of the passwords and of the network parameters is necessary for remote access with SMAVIA Viewing Client.
  • Page 23 DIS-4/M SRS ➡ Click Later to login without changing a password. The configuration interface is displayed. ➡ Observe the appropriate “Configuration” documentation. ➡ Continue accordingly for the remaining modules. www.dallmeier.com...
  • Page 24: Specifications

    DIS-4/M SRS 11 Specifications Components Multi-Core 4 GB Flash module 8 GB (for operating system and application) Hard disks Up to 2× 3.5” HDD (optional) Max. storage capacity Currently up to 12 TB Integrated in module rack (hardware 002150) Power supply unit Integrated in module rack (hardware 002150)
  • Page 25 +20°C up to + 25°C (68°F − 77°F) Humidity 5 − 70% RH, non-condensing Atmospheric load Dust-free Approvals and Certifications Type CE, UL, FCC, ACA, LGC Forensics, DIN EN 50130-4 For detailed technical data and possible updates, see the current “Specification” document available at www.dallmeier.com. www.dallmeier.com...
  • Page 26: Maintenance

    DIS-4/M SRS 12 Maintenance The device may only be opened by qualified personnel for commission- ing, inspection, maintenance and repair.  WARNING Danger of electric stroke The module carrier is equipped with redundant power supply units. ➡ Ensure that all supply lines are disconnected from the supply circuit.
  • Page 27 DIS-4/M SRS Notes www.dallmeier.com...
  • Page 28 Dallmeier electronic GmbH & Co.KG Bahnhofstr. 16 · 93047 Regensburg · Germany Phone +49 (0) 941 87 00-0 · Fax +49 (0) 941 87 00-180 www.dallmeier.com · info@dallmeier.com...

Table of Contents