10. Electrical wiring

10.3 Printed circuit board (PCB)

10.3.1 Outdoor unit


RAS-(4-6)H(V)RNME-AF
Connector indication
PCN1
Fuse
PCN2
PCB1 connection from outdoor to indoor unit
PCN5
Crankcase heater of compressor (oil)
PCN6
Output optional function
PCN7
Output optional function
PCN8
Pressure switch protection
PCN9
Compressor contactor
PCN13
Pressure switch control
THM7
Outdoor air temperature thermistor
THM8
Pipe evaporation temperature thermistor
THM9
Compressor discharge temperature thermistor
CN2
Current transformer
CN5A
Micro electronic expansion valve
CN8
Transmission from outdoor to indoor unit
CN14
Transmission between PCB1 and ISPM
EFS1, 2
Power protection
118
TCGB0075 rev.0 - 11/2012
Switch indication
DSW1
Test run
(PCB1)
DSW2
Piping length and selection function
DSW3
Capacity code
DSW4/
Refrigerant cycle number
RSW1
DSW5
End terminal resistor
DSW6
Power source setting
LED indication
This LED indicates the transmission status bet-
LED1
Red
ween the indoor unit and the RCS
This LED indicates the transmission status bet-
LED2
Yellow
ween the indoor unit and the outdoor unit
LED3
Green
Power source for the PCB