Logic
Definition

Serial mode

SERIAL MODE
(Identifies how board
is configured in a BFT
network connection).
ADDRESS
Address
Configuration of
EXPI1 input on
EXPI1
input-output expan-
sion board.
1-2
Configuration of
EXPI2 input
EXPI2
on input-output
expansion board.
1-3
28 -
LEO B CBB 3 230 L02/L04 - LEO B CBB 3 120 F02 / F04
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
1
boards.
0
 
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
2
with no smart module (fig.F)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves net-
3
work with no smart module (fig.F)
Identifies board address from 0 to 127 in a local BFT network connection.
[ ___ ]
0
 
(see U-LINK OPTIONAL MODULES section)
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
1
 
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
11
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
12
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
13
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
14
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
0
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).