Serial Mode - BFT LEO B CBB 3 230 L01 Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
Logic
Definition
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
safety input SAFE 3.
SAFE 3
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
command input IC 3.
IC 3
Configuration of
command input IC 4.
IC 4
Protection
Setting the
protection level
level

Serial mode

(Identifies how board
SERIAL MODE
is configured in a BFT
network connection).
Address
ADDRESS
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
18 -
LEO B CBB 3 230 L01
INSTALLATION MANUAL
Cross out
Default
setting
used
0
1
0
2
72
3
 
4
5
6
6
74
7
8
0
1
2
3
2
 
4
77
5
6
7
0
0
1
61
2
4
3
62
 
4
2
5
64
3
6
65
1
2
3
4
0
0
1
[ ___ ]
0
0
1
2
3
4
5
6
7
8
1
9
1-2
10
11
12
13
14
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2.
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Input configured as Timer Pedestrian.
Not used
Not used
Not used
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
E - The option of editing the board's parameters via the U-link network is disabled.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
Identifies board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Optional extras

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U-link leo b cbb 3 230 l01

Table of Contents