2) GENERAL INFORMATION

The LEO B CBB 3 230 L02 - LEO B CBB 3 230 L04 - LEO B CBB 3 120 F02 - LEO B
CBB 3 120 F04 control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 single-phase motor
-
Electronic torque control
-
Obstacle detection (only on LEO B CBB 3 230 L02 e LEO B CBB 3 120 F02)
-
Separate inputs for safety devices
-
Configurable command inputs
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
LEO B CBB 3
LEO B CBB 3
230 L02
120 F02
Power supply 230V~ ±10%
120V~ ±10%
50Hz/60Hz
50Hz/60Hz
Obstacle
Present
Present
detection with
encoder
Output for
AUX3
Output for
terminals 26-27:
configurable
audible signal
N.O. contact
(24V~/0,5A)
TESTING
The LEO B CBB 3 230 L02 - LEO B CBB 3 230 L04 - LEO B CBB 3 120 F02 - LEO
B CBB 3 120 F04 panel controls (checks) the start relays and safety devices
(photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
WIRING AND TERMINAL BOARD CONFIGURATION
Terminal
Definition
L
LINE
N
NEUTRAL
GND
EARTH
10
START + CAP
11
COM
12
START
13
CAP
20
LIGHT 230V
21
FREE
26
CONTACT (N.O.)
27
(Max 24V 0,5A)
41
+ REF SWE
42
SWC
43
SWO
50
24V-
51
24V+
52
24 Vsafe+
60
Common
61
IC 1
62
IC 2
63
Common
64
IC 3
65
IC 4
INSTALLATION MANUAL
LEO B CBB 3
LEO B CBB 3
230 L04
120 F04
230V~ ±10%
120V~ ±10%
50Hz/60Hz
50Hz/60Hz
Not present
Not present
AUX3
AUX3
configurable
configurable
Single-phase power supply 230V~ ±10%, 50-60Hz, with earth cable
(LEO B CBB 3 230 L02, LEO B CBB 3 230 L04).
Single-phase power supply 120V~ ±10%, 50-60Hz, with earth cable
(LEO B CBB 3 120 F02, LEO B CBB 3 120 F04).
Motor connection.
START + CAP Motor Start and capacitor
COM Motor Common
START MOTOR START
CAP capacitor
Flashing light 230V output max. 40W (LEO B CBB 3 230 L02, LEO B CBB 3 230 L04).
Flashing light 120V output max. 40W (LEO B CBB 3 120 F02, LEO B CBB 3 120 F04).
Contact N.O. (24V~/1A).
"AUX3" (LEO B CBB 3 230 L02, LEO B CBB 3 230 L04, LEO B CBB 3 120 F04) FIG. B1
Output for acoustic signal (LEO B CBB 3 120 F02) FIG. B2
Limit switch common
Closing limit switch SWC (N.C.)
- Opening limit switch SWO (N.C.)
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Maximum motor power
Accessories power supply
AUX 3/ Output for audible signal
Flashing light
Dimensions
Fuses
N° of combinations
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Description
LEO B CBB 3 230 L02/L04 - LEO B CBB 3 120 F02 / F04
230V~ ±10% 50Hz/60Hz
(LEO B CBB 3 230 L02, LEO B CBB 3 230 L04)
120V~ ±10% 50Hz/60Hz
(LEO B CBB 3 120 F02, LEO B CBB 3 120 F04)
> 2MOhm 500V
-20 / +55°C
Built into motor
mains/LV 3750V~ for 1 minute
750W
24V~ (demand max. 1A)
24V~safe
NO contact (24V~/max.0,5A)
230V~ 40W max
146x170x60mm
see Fig. B
4 billion
23
-